![Saferoads HV2 Safety Barrier Product Manual Download Page 12](http://html.mh-extra.com/html/saferoads/hv2-safety-barrier/hv2-safety-barrier_product-manual_798688012.webp)
W
www.saferoads.com.au
T
+61 3 5945 6600
E
USA Version 1.4
March 2019
Page 11
QuadGuard Crash Cushion Deployment
When deploying the system with a QuadGuard Crash Cushion, a HV2 Transition must be used between the
QuadGuard and the end HV2 Barrier segment. A 24in (610mm) QuadGuard (model number QS2406) should be used.
1.
Replace the side panels (part number 2760141-0000) between the rearmost fender panels and the tension
strut backup of the QuadGuard with the HV2 Transition. This transition can remain attached to the
QuadGuard, including during transport.
QuadGuard parts excluded for clarity
2.
Align the connectors of the HV2 Transition with the connectors of the end HV2 Barrier segment while
lowering the QuadGuard and HV2 Transition assembly into position.
3.
Anchor both the HV2 Transition and the QuadGuard. The HV2 Transition should be anchored using Hilti HIT-
RE 500 V3 epoxy or equivalent. QuadGuard should be anchored according to the QuadGuard product
manual.
Surface
Minimum Foundation Depth
Anchor
Concrete
6in (150mm) Concrete
7in (180mm) Stud
5.5in (140mm) Embedment
Asphalt Over
PCC
3in (76mm) Asphalt
3in (76mm) Concrete
18in (460mm) Stud
16.5in (420mm) Embedment
Asphalt Over
Subbase
6in (150mm) Asphalt
6in (150mm) Compacted Subbase
18in (460mm) Stud
16.5in (420mm) Embedment
Asphalt
8in (200mm) Asphalt
18in (460mm) Stud
16.5in (420mm) Embedment