SAFEGREASE, SAFEOIL, MULTILUBE
ST-1340
13401BEN.doc
27.12.2004 Rev. 1B
17 (19)
Display function keys
Key Description
Chnl
Channel
selection
Press key to display the configuration settings for the next channel.
Channel can also be selected with
Í
and
Î
keys, which can used for toggling
between channel up and down.
Set
Configuration
mode
Press key to go into configuration settings mode in which you can change the
configuration settings for the selected channel. The program requires a separate
password before it accepts this command.
Esc
Back to basic display
Press key to return to the basic display.
Configuration settings
Note
Configuration settings should be changed only when changes are made to
the system, for example, additional channels and pumping centers are
installed. These changes are usually implemented by the supplier.
Configuration mode requires a password
1341
or
1441
.
Each channel can be set to different operation modes regardless of the settings of the other
channel.
Display code
Selected operation mode
SG1
Single line grease lubrication channel
SG2
Dual line grease lubrication channel
SG2E
Dual line grease lubrication channel,
pressurization maintaining operation
OS
oil lubrication channel
ML1
Single line MultiLube
ML2 Dual
line
MultiLube
In ST-1340 control center all channels are in group 1.
Channel line and pump control are switched on at the set pump control channel.
The channel-specific alarm relay can be set as alarm (
Relay 0
) or status output (
Relay 1
).
The pressure control unit can selected to be pressure transmitter (
P-transm.
) or pressure
switch (
P-switch
).
The center specific configuration settings include
•
display
language
•
date
and
time
•
delay multiplier, factory setting = 3
•
pressure
unit