MULTILUBE
INSTALLATION AND MAINTENANCE
HINS4AEN.doc
24.08.2006 Rev. 4A
7 (18)
2.2 Installing the cables and electrical connections
Warning
Electrical connections to the terminal blocks may only be made by a
qualified electrician.
1. Remove the cover, see paragraph 2.1 .
2. Remove the protective plug of the cable gland (Figure 15).
3. Bend the cable end a little curved (Figure 16). This makes the feeding of the cable easier.
4. Push the cable through the cable gland to the terminal block (Figures 17 and 18).
5. Put an appropriate screwdriver in the upper opening of the terminal block.
Caution
Do not twist the screwdriver, only put it in the opening.
6. The cable to be connected is put in the lower opening. The cable is locked when the
screwdriver is detached from the upper opening (Figure 19).
Figure 15.
Removing the
protective plug
Figure 16.
Feeding the cable
Figure 17.
Feeding the cable
through the cable
gland
Figure 18.
Cable at the terminal
block