Safelock Systems Tecnosicurezza TechMaster User Operating Instructions Download Page 2

Available users and default codes 

 
User 

ID 

Code 

Master 

N/A 

12345678 

Manager 

N/A 

123456 

Users 02 - 90 

02-90 

Users  must  be  added  by 
the Manager 

 

Default codes must be changed immediately. 

 

Using the keypad 

 
Press any key to wake the display to the Home Screen 
If  a  key  is  not  pressed  for  30  seconds,  the  keypad 
display will automatically switch off. 

To access the main menu press 

 

To scroll menu items press 

 

To accept press 

 

To exit a menu or function, press and hold  

 or scroll 

to EXIT. 
 

Shortcuts for Special Functions 

 
Press and hold the relevant key to access the shortcut. 
 

Key 

Special Function 

Change Code 

Test the keypad 

Access the Manager menu 

View keypad firmware version 

 

To open the lock 

 

Enter  a  valid  User  ID  and  6-digit  code,  or  press 

  to 

enter the Manager code. 
 

To open the lock if time delay is active 

 
Enter  a  valid  User  ID  and  6-digit  code,  or  enter  the 
Manager code. Wait for the time delay period to elapse. 
The  open  window  will  be  indicated  with  the  onscreen 
message  “OPEN  WINDOW”  and  double  beeps  at  5 
second intervals. 

Enter  a  valid  User  ID  and  6-digit  code  or  press 

  to 

enter the manager code. 

To  stop  time  delay  counting,  press 

  then 

  to 

confirm. 
 

To change code 

 

Shortcut:

 Press and hold 0 or; 

Press 

 to access the main menu, scroll to CHANGE 

CODE. Press 

 to accept. 

Scroll  to  CHANGE  USER  or  CHANGE  MANAGER  or 

CHANGE MASTER. Press 

 to accept.  

Enter the ID if required and enter the old code. 
Enter the new code twice. 

To access the Manager Menu 

 

Shortcut:

 Press and hold 6 or; 

Press 

 to access the main menu, then 

 to scroll to 

the Manager menu.  

Enter the Manager code. Press 

 to scroll through the 

menu options and 

 to make a selection. 

 

The Manager can: 

 

  Open the lock 

  Manage Users 

  Adjust time delay settings 

  Start a connection to a PC to take an audit  

  View an onscreen audit 

 

To manage Users (Manager Only) 

 

Access  the  Manager  menu,  scroll  to  USERS 

MANAGEMENT. Press 

 to accept.  

 

The following symbols indicate the status of each user 

 

 

Press 

 to advance each page. 

Enter the ID of the User to be added (Use 2 digits). The 
cursor will flash underneath the User ID.  

Press

 

 

to access options.  

Press 

 

to  scroll  through  options  and  follow  the 

onscreen instructions. 
INSTALL 

– add a User code. The user must enter their 

code twice. 
DELETE 

–  if  a  User  is  installed,  their  code  can  be 

deleted, making it possible to add a new different code. 
DISABLE 

–  If  a  User  is  installed,  their  code  can  be 

temporarily disabled. 
ENABLE 

–  If  a  User  code  has  been  temporarily 

disabled, it can be re-enabled. 

 
To add time delay values 

 
Access  the  Manager  menu,  scroll  to  T.  DELAY  AND 

O.WINDOW, press 

 to accept. The display will show 

the current time delay values. 

Press 

 

Enter time delay value e.g. 01 minute (Max. 99 minutes) 
Enter open window value e.g. 01 minute (The minimum 
open window value is 01, the maximum  is 19). 

Press 

 to accept. 

 

Note:

  If  the  time  delay  values  are  to  be  reduced,  the 

lock must first be unlocked during the open window and 
the bolt must be held  in the open position before again 
accessing the time delay menu. 

Symbol 

Status 

No Symbol 

User deleted 

 

User installed and enabled 

User disabled 