Reset a User code (#57)
Master/Manager
If a User has forgotten their code, it is possible to reset it
rather than deleting and adding the User again.
•
Enter #57
•
Enter the Master or Manager ID and code
•
Enter the current ID and new code
twice
•
Press Enter.
If accepted, the lock will signal 3 green
f short beeps
☼☼☼
Example to reset a user code:
After the code has been reset successfully, the User
must change the code before it can be used to open
the lock. Use a simple code such as 02-020202.
Set date and time (#65)
Master/Manager
To maintain the integrity of the audit, it is important to
ensure that date and time is set on an annual basis and
re-established after a power loss lasting for more than a
few minutes.
•
Enter #65
•
Enter the Master or Manager ID and code
•
Enter 10 digits to reflect the date and time in the format
(YY) (MM) (DD) (24HR)
•
Press Enter.
If accepted, the lock will signal 3 green
f short beeps
☼☼☼
Example date and time:
22
nd
July 2021, 2:30pm
2107221430
Example to set date and time:
Amend time delay values (#72)
Master/Manager
Time delay is a feature that requires a period of time to
elapse before the lock can be opened, to prevent Users
from being coerced into opening the safe or vault
immediately.
Add time delay values
•
Enter #72
•
Enter the Master or Manager ID and code
•
Enter 2 digits to indicate the time delay (00-99 minutes)
•
Enter 2 digits to indicate the open window (01-60
minutes)
•
Press enter.
If accepted, the lock will signal 3 green
f short beeps
☼☼☼
Example to add time delay:
Time delay values cont.
Master/Manager
If time delay values need to be reduced or removed, the
procedure can be carried out at any time, but one complete
cycle (Time delay, open lock) of the previous settings must
occur before the new settings take effect.
To remove time delay:
•
2 digits for the time delay: 00
•
2 digits for the open window: 01
Cancel time delay counting (#74)
All
If time delay has been initiated but is no longer required, it
can be cancelled.
•
Enter #74
•
Enter any valid ID and code
•
Press Enter.
If accepted, the lock will signal 3 green
f short beeps
☼☼☼
Example to cancel time delay counting:
Troubleshooting
Key press results in 2 red f short beeps
☼☼
The lock is in penalty caused by 4 consecutive incorrect
code entries. Wait for the 5-minutes penalty period to
elapse. After the penalty has elapsed, 2 further wrong
codes will again initiate a penalty. The trigger will reset
after a valid code has been entered.
3 red f short low beeps
☼☼☼
The code or command has not been entered correctly, re-
enter.
If a mistake is made during code or function entry
Press # to cancel
A key does not beep when pressed
If the LED still flashes, keypad beeps may have been
turned off. If there is no flash, the batteries may be
depleted. Change the batteries then set the date and time
to ensure accuracy of the audit data.
The safe or vault door does not open
If the lock system is otherwise operating normally, there
may be a mechanical fault with the safe. Contact a safe
engineer.
Document version
These instructions may be updated from time to time to
reflect firmware changes, visit
check for updates or download additional instructions such
as
Advanced Operation.