Commands
Non-opening functions are available to Users depending
on their profile, with # commands. These instructions
cover the commands listed below:
Category
Key
Function
Codes
#52
Change code
User
management
#50
Add a User
#54
Disable or re-enable a User
#55
Change user privilege
#56
Delete a User
#57
Reset a User code
Time delay
#72
Amend time delay values
#74
Cancel time delay counting
General
operation
#40
Disable or enable backlit buttons
#41
Turn keypad beeps off or on
#65
Set time and date
Advanced
commands
are
available
in
separate
instructions:
Advanced Operation
available to download
from our website.
Adv
a
nc
e
d
Com
m
a
nd
s
Category
Key Function
Codes
#11
Change code length
#12
Enable or disable dual mode
General
operation
#14
Enable or disable the Duress
feature
#16
Specify alarm input setting
Audit
#30
Activate PC link
Manager
Management
#50
Add a Manager
#54
Disable or re-enable a Manager
#55
Change Manager privilege
#56
Delete a Manager
#57
Reset a Manager code
Time delay
#73
Enable time delay override
feature
Additional commands #22, #23, #25, #32, #99 are
available to the Master, which should only be used by
engineers who are servicing the lock.
Visual and acoustic signals
Lock status is indicated with LED flashes and beeps.
Signal
Symbol
Green flash + short high beep
Meaning: Button pressed correctly
☼
Red flash + short low beep
Meaning: Invalid key
☼
3 green f short high beeps
Meaning: Command or code accepted
☼☼☼
3 red f short low beeps
Meaning: Invalid code or command
☼☼☼
2 red flashes + short low beeps on a key
press
Meaning: The lock is in penalty
☼☼
2 green flashes + high beeps then 2 red
f short low beeps
Meaning: Low battery
☼☼
☼☼
3 green flashes + high beeps then 3 red
f short low beeps
Meaning: Critical low battery
☼→☼→☼→
☼→☼→☼→
Red flash + short low beep
(Every 10 seconds)
Meaning: Time delay is counting
☼
Green flash + short high beep
(Every 10 seconds)
Meaning: The open window is counting
☼
Open the lock
Manager/Users
Depending on the construction of the safe or vault, other
locks such as key locks may need to be opened first. Any
actions required to open the door and lock should be
reversed to close and secure the door and lock.
•
Enter a Valid ID and code
•
If accepted, the lock will signal 3 green f
short beeps
☼☼☼
•
Within 3 seconds, turn the keypad and/or turn the safe
handle
Open the lock when time delay is active
•
Enter a valid ID and code.
The lock will signal 3 red
flashes +
short low beeps
☼☼☼
after the code is
entered, followed by
1 red flash + short low beep every
10 seconds
☼
•
Once the time delay has elapsed the lock will signal the
open window with
1 green flash + short high beep every
10 seconds
☼
•
During the open window
, enter a Valid ID and code
•
If accepted, the lock will signal 3 green f
short beeps
☼☼☼
•
Within 3 seconds, turn the keypad and/or turn the safe
handle
Override time delay
If the feature has been enabled using #73 see
Advanced
Operation
, and a User has been profiled with the privilege
to override time delay, their code is valid to open the lock
immediately using the standard open lock instruction.
Open the lock if operating in dual mode
•
Enter a valid ID and code
(No signal)
•
Enter a 2
nd
valid ID and code
•
If both codes are accepted, the lock will signal 3 green
f 3 short beeps
☼☼☼
•
Within 3 seconds, turn the keypad and/or turn the safe
handle
Dual mode for the Manager
Manager
If the lock has been set to operate dual mode for Users +
Manager, to carry out any commands, the Manager must
enter their ID and code
first
, followed by a second valid ID
and code, before the rest of the command process is
followed.
Example to add a standard opening user: