background image

Commands

 

 

Non-opening  functions  are  available  to  Users  depending 
on  their  profile,  with  #  commands.  These  instructions 
cover the commands listed below: 

 

Category 

Key 

Function 

Codes 

#52 

Change code 

User 

management 

#50 

Add a User 

#54 

Disable or re-enable a User 

#55 

Change user privilege 

#56 

Delete a User 

#57 

Reset a User code 

Time delay 

#72 

Amend time delay values 

#74 

Cancel time delay counting 

General 

operation 

#40 

Disable or enable backlit buttons 

#41 

Turn keypad beeps off or on 

#65 

Set time and date 

 

 

Advanced 

commands 

are 

available 

in 

separate 

instructions: 

Advanced Operation 

available to download 

from our website. 

 

 

Adv

a

nc

e

Com

m

a

nd

s

 

Category 

Key  Function 

Codes 

#11 

Change code length  

#12 

Enable or disable dual mode 

General 

operation 

#14 

Enable  or  disable  the  Duress 
feature 

#16 

Specify alarm input setting 

Audit 

#30 

Activate PC link 

Manager 

Management 

#50 

Add a Manager 

#54 

Disable or re-enable a Manager 

#55 

Change Manager privilege 

#56 

Delete a Manager  

#57 

Reset a Manager code 

Time delay 

#73 

Enable  time  delay  override 
feature 

 

Additional  commands  #22,  #23,  #25,  #32,  #99  are 
available  to  the  Master,  which  should  only  be  used  by 
engineers who are servicing the lock.  

 

Visual and acoustic signals

 

 
Lock status is indicated with LED flashes and beeps. 
 

Signal 

Symbol 

Green flash + short high beep 

Meaning: Button pressed correctly 

 

Red flash + short low beep 

Meaning: Invalid key

 

 

3 green f short high beeps 

Meaning: Command or code accepted

 

☼☼☼

 

3 red f short low beeps 

Meaning: Invalid code or command

 

☼☼☼

 

2  red  flashes  +  short  low  beeps  on  a  key 
press 

Meaning: The lock is in penalty

 

☼☼

 

2  green  flashes  +  high  beeps  then  2  red 
f short low beeps 

Meaning: Low battery

 

☼☼

☼☼ 

3  green  flashes  +  high  beeps  then  3  red 
f short low beeps 

Meaning: Critical low battery

 

☼→☼→☼→ 

☼→☼→☼→

 

Red flash + short low beep

 

(Every 10 seconds)

 

Meaning: Time delay is counting

 

 

Green flash + short high beep 

(Every 10 seconds)

 

Meaning: The open window is counting 

 

Open the lock

                     

 

Manager/Users

 

 
Depending on the construction of the safe or vault, other 
locks such as key locks may need to be opened first. Any 
actions  required  to  open  the  door  and  lock  should  be 
reversed to close and secure the door and lock. 

 

  Enter a Valid ID and code  

 

If accepted, the lock will signal 3 green f

 

short beeps 

☼☼☼

 

  Within 3 seconds, turn the keypad and/or turn the safe 

handle 

 

Open the lock when time delay is active

                 

 

  Enter  a  valid  ID  and  code. 

The  lock  will  signal  3  red 

flashes  + 

short  low  beeps

 

☼☼☼ 

after  the  code  is 

entered, followed by

 

1 red flash + short low beep every 

10 seconds 

 

  Once the time delay has elapsed the lock will signal the 

open window with 

1 green flash + short high beep every 

10 seconds 

 

 

During the open window

, enter a Valid ID and code  

 

If accepted, the lock will signal 3 green f

 

short beeps 

☼☼☼

 

  Within 3 seconds, turn the keypad and/or turn the safe 

handle 

 

Override time delay

                     

  

 
If the feature has been enabled using #73 see 

Advanced 

Operation

, and a User has been profiled with the privilege 

to override time delay, their code is valid to open the lock 
immediately using the standard open lock instruction. 
 

Open the lock if operating in dual mode

 

 

  Enter a valid ID and code 

(No signal) 

  Enter a 2

nd

 valid ID and code 

 

If both codes are accepted, the lock will signal 3 green 
f 3 short beeps 

☼☼☼

 

  Within 3 seconds, turn the keypad and/or turn the safe 

handle 

 

Dual mode for the Manager

 

           

Manager

 

 
If the lock has been set to operate dual mode for Users + 
Manager, to carry out any commands, the Manager must 
enter their ID and code 

first

, followed by a second valid ID 

and  code,  before  the  rest  of  the  command  process  is 
followed. 

 
Example to add a standard opening user: 

 

 

 
 

 
 

       

 

  

 

 

 

   

 

    

       

 

  

 

 

 

   

 

    

       

 

  

 

 

 

   

 

    

   

 

  

 

 

 

    

  

 

 

 

    

        

 

   

 

    

 

      

       

 

  

 

 

 

   

 

    

       

 

  

 

 

 

   

 

    

   

 

  

 

 

 

    

Reviews: