background image

UNIVERSAL+ 7WR 1PHAD 

 
 

 

 

User’s installation manual - UN 7WR 1PHAD

 

 

It is imperative that the user/installer fully understand the present manual as also its pertinent accessories 
manuals prior to using the unit. Should any doubt arise, please refer to the  Authorised Distributor or the 
Manufacturer.

   

All  rights  reserved.    No  part  of  this  publication  may  be  reproduced,  stored  in  a  retrieval  system,  or  transmitted  in  any  form  or  by  any  means  electronic, 
mechanical,  recording  or  photocopying  or  otherwise  without  the  express  prior  consent  of  Safeline,  S.L.   Whilst  every  care  has  been  taken  to  ensure  that  the 
information contained herein is correct, no liability can be accepted by Safeline, S.L. for any damage caused by any errors in, or omissions from, the information 
given. Neither is Safeline, S.L. liable for any damage arising from the incorrect use of this information. 

Safeline, S.L., as also its affiliates, is not liable to the purchaser or to third parties for damages, be they material or personal, costs, etc. in which the purchaser or 
third party may incur as a result of any accident or incorrect use of this product, nor as a result of any unauthorised modification, alteration or repair to same, nor 
due to non-observance of the operation and maintenance instructions given by Safeline, S.L.  

Always with an aim to improving the quality of its products, Safeline reserves the right to modify,  without previous notice, any standard or characteristic in the 
present manual and the products indicated herein. The technical characteristics set out in said standards are for information purposes. 

Sureline is a trademark of Safeline, S.L. 

Published in Spain by Safeline, S.L.    2

nd

 edition (May 2020) 

 

 

Summary of Contents for Universal+ 7WR 1PHAD

Page 1: ...ng file import and export function Four independent time programmers Astronomical daily weekly Daily weekly 295 programs Daily monthly yearly 1145 programs Daily monthly yearly vacations holidays 285 programs Counter for ON hours information and manual control WebServer programming control and total monitoring in real time via Internet Intranet UNIVERSAL 7WR 2PHA y UNIVERSAL 7WR 2PH With software ...

Page 2: ...ns from the information given Neither is Safeline S L liable for any damage arising from the incorrect use of this information Safeline S L as also its affiliates is not liable to the purchaser or to third parties for damages be they material or personal costs etc in which the purchaser or third party may incur as a result of any accident or incorrect use of this product nor as a result of any una...

Page 3: ...B page Box Manual control 17 WEB page Box Daily weekly astronomical time programmer 18 WEB page Box Daily weekly time programmer 21 WEB page Box Daily monthly yearly time programmer 21 WEB page Box Time programmer for exceptions vacations holidays 22 WEB page Box Unit configuration 23 CHAPTER 3 USER S GUIDE front panel and LCD screen Function of the buttons 24 User PIN 24 LCD screen 12x3 character...

Page 4: ...RNET INTRANET CONFIGURATION Point to point configuration 33 Internet Intranet connection configuration 35 Remote access configuration 35 More than one WebServer in the same network 36 TCP IP configuration When the ex factory IP domain is not within the IP range of user s network 36 Aid for a correct configuration 37 Aid FAQ 37 CHAPTER 7 DIAGNOSES AND TROUBLE SHOOTING Informative messages 38 CHAPTE...

Page 5: ...yearly vacations holidays 285 programs 7WR 1PHAD 1 2 1 Load intensity output relay RA 6A 6A Max AC1 250V AC Max 16A 16A Max AC1 250V AC Max 2 Supply voltage terminals line neutral 230VU Universal AC and DC power supply 85V 265V AC 47 440HZ and 130V 370V DC 12V 12V DC 9V 18V DC 24V 24V DC 18V 36V DC 48V 48V DC 36V 72V DC e g UNIVERSAL 7WR 1PHAD 6A 230VU Attention please consult identifying label on...

Page 6: ...atsoever Presentation standard EN 50 022 enclosure for 35mm DIN rail This is a compact unit monitored by a 16 Bit Microcomputer and is highly stable thanks to its built in double process monitor Watchdog The UNIVERSAL 7WR family is a series of units with WebServer designed to provide electrical protection control and monitoring in real time via Internet Intranet permitting electrical installations...

Page 7: ...gramador horario diario mensual yearly excepciones holidays vacations 285 programs Counter for number of ON hours WebServer Programming control and total monitoring in real time via Internet Intranet Information regarding status of relay and dimmer with number of ON hours automatically refreshed every 2 secs Manual control via Internet Intranet and through the unit itself Easy clear and simple pro...

Page 8: ...tput 0 10V for a day month year Daily monthly yearly time programmer exceptions holidays vacations Permits the user to program daily switching on and off of relay A and to program Start Stop and Speed percentage increase decrease in s of the dimmer output 0 10V for a day month year Simultaneous execution These time programmers operate in parallel so that all programs run without delay except in th...

Page 9: ...ed by indicating None in the relay selector Geographical location The user must specify the location where the unit is to calculate the sunrise and sunset This device s process of acquisition of coordinates is automatic if Automatic is pressed They can however also be entered manually Adjustment of relay and dimmer according to days of the week These are adjusted as per user s requirements on days...

Page 10: ...rds should one require it not to come into operation on a holiday Holidays are configured in the vacations time programmer Results The astronomical programmer is now configured All that remains is to indicate whether automatic Summer or Winter switchover time is required The unit will calculate sunrise and sunset daily every year from this point on ...

Page 11: ...e that a new plant is put in which requires more frequent watering In this case all days of the week are selected relay A is set to ON for example at 19 00 After this the process is repeated but at 19 05 relay A switches to OFF thus avoiding the irrigation being left on all night The dimmer controls a light which will switch on at 11 05 going from 0 to 100 in 60 secs It will then remain at 100 unt...

Page 12: ...mitted by indicating None in the relay selector Import export If a program has already been exported and one wishes to import it one must first import a configuration file by pressing Select file and selecting one Thus one can easily program diverse units or simply make backup copies Programming Programming is simple For example in the hottest months June July and August the irrigation system star...

Page 13: ... and one wishes to import it one must first import a configuration file by pressing Select file and selecting one Thus one can easily program diverse units or simply make backup copies A la hora de programar Programación muy sencilla Por ejemplo Si durante los días de vacaciones de una empresa se desea hacer un control del relay y el dimmer diferente lo único que tendrá que hacerse es seleccionar ...

Page 14: ... programmers 2 3 and 4 are omitted This latter 4 however does have a programmable option whereby it can avoid being omitted Hour Minutes clock Next reading clock N Precision reading clock Day Date Month Year Hour Minutes Time prog Vacations holidays Daily Monthly Yearly Day Month Year clock Time prog Daily Monthly Yearly Day Month Year clock Time prog Daily Weekly Day of the Week clock N N Y Y ON ...

Page 15: ...tablet or PDA conveniently easily and clearly In order for the data dispatch and command reception of the WebServer to function correctly a good quality Internet connection or an Internet line connection optic fibre or similar is imperative It has three customizable styles for its display on the website These styles are memorised in each browser through the use of cookies Safeline Minimalist Class...

Page 16: ... opens up and the user PIN is requested The user PIN represents a high degree of security for the owner since this is the sole means whereby the programmed parameters can be validated Any changes in programmed values only come into effect once said PIN has been entered Made up of 4 digits each one from 0 to 9 o Default PIN enabled at factory 1 2 3 4 o The user PIN can be changed if one is in posse...

Page 17: ...tuitive since it is organized with the following 8 main buttons WEB page Box information Displayed here are the date and time of the internal clock name status and number of ON hours of relay A name status programming and ON hours 5 of the dimmer The green background is refreshed every 1 sec WEB page Box Manual control Permits the user to switch relay A ON or OFF and also to program all the dimmer...

Page 18: ...titude longitude and GMT selectors If the programming is effected at this location the coordinates can be obtained automatically Select the days of the week enable prog 1 s general box configure status offset and dimmer enter user PIN and press save changes in order to send and save settings NOTE The internal calculation effected by the unit can differ by 1 o 2 mins from the result shown on the we...

Page 19: ...UNIVERSAL 7WR 1PHAD 19 ...

Page 20: ...UNIVERSAL 7WR 1PHAD 20 ...

Page 21: ...sed to save the programming on file This txt file can be imported to the same unit or exported to others WEB page Box Daily monthly yearly time programmer Once the page has been loaded the Programs listing shows current programming saved in the unit By means of the selectors for day month year hour relay ON OFF and Dimmer Start Stop Speed the desired program can be constructed By pressing Add prog...

Page 22: ...year hour relay and ON OF and Dimmer Start Stop Speed the desired program can be constructed By pressing Add program Delete program and Modify program the user interacts with said Programs listing Enter user PIN and press Save changes to send and save the program listing in the unit The export program button is used to save the programming on file This txt file can be imported to the same unit or ...

Page 23: ...t name relay name dimmer name TCP IP and user PIN Manual or automatic programming of internal clock synchronizing the date and time with those of the user s PC laptop etc Automatic Winter Summer switchover time can be enabled or disabled manually Enter current user PIN and press Save to send and save changes to unit ...

Page 24: ...nges General reset Hold RESET OK key down for more than 10 seconds Very important The general reset restores the TCP IP parameters to default factory values The user PIN is not reset Default factory configuration IP 192 168 2 10 Gateway 192 168 2 1 Mask 255 255 255 0 Port 80 User PIN The user PIN represents a high degree of security for the owner since this is the sole means whereby the programmed...

Page 25: ...ubmenu press OK The ESC key permits the user to quit the submenu or menu In order to confirm the modification of a flashing value press OK NOTE To save all changes in memory press ESC until all submenus and the menu have been quitted When ESC is pressed this last time the unit asks whether one wishes to save the changes and requests the PIN If the current PIN is not entered the changes will not be...

Page 26: ...essed in TCP IP information the following information is displayed the displayed parameters are default ex factory Port 80 pressing OK in this parameter its value can be modified IP 192 168 2 10 pressing OK in this parameter its value can be modified Gateway 192 168 2 1 pressing OK in this parameter its value can be modified Mask 255 255 255 000 MAC xx xx xx xx xx xx When OK is pressed in LED Lan ...

Page 27: ...commended on a permanent basis in an installation due to problems which could be caused by unauthorised personnel ATTENTION For security reasons no master PIN exists In case of loss the user must contact the manufacturer to have the unit re programmed and thoroughly verified It is recommended that this PIN be noted down and kept in a safe place Acoustic warnings beep This submenu permits the acous...

Page 28: ...ase speed s 0 0V at100 10V in 1 steps 0 000 s 999 9 s 4 digits 0 or 100 0 with 999 9 s 27 7 hours resolution 0 001 s 0 100 or 100 0 with 0 000 s instantaneous resolution 0 001 s 12x3 character LCD screen 5X7 matrix Green Working LED Working Blinks every 1 sec Dimensions UNIVERSAL 7WR 1PHAD 72mm 4 modules height 81mms 35mm DIN rail Weight UNIVERSAL 7WR 1PHAD 375 grs Configurable languages Spanish a...

Page 29: ...d due to failure of the internal battery this recovery does not take place the relay statuses are reset to OFF and programs continue as from the current date Description of connection terminals UNIVERSAL 7WR 1PHAD L POWER 230V PHASE POWER LINE 230V AC 50Hz N POWER 230V NEUTRAL POWER UNIDENTIFIED TERMINAL DO NOT CONNECT 9 RELES OUT DO NOT CONNECT 8 RELES OUT DO NOT CONNECT 7 RELES OUT DO NOT CONNEC...

Page 30: ...istics Do not exceed the maximum intensity in the output contacts of relay A In the event of electrostatic discharges or electromagnetic emissions it may well happen that the LCD screen goes blank without control without this affecting the functioning of the unit itself In order to reset the LCD screen press the MENU key Nevertheless the unit resets the LCD cyclically every 15 minutes Do not expos...

Page 31: ...ipulated in the foregoing section PRECAUTIONS Installation The installation must be carried out by responsible competent and qualified technical personnel once the present manual has been fully understood The location of the unit must meet the requirements and respect the precautions stipulated in the section PRECAUTIONS The unit must be installed in a standard single phase installation active pha...

Page 32: ...CT F A B C D BORNA TERMINAL AUXILIARY IN OUT ANALOGUE OUTPUT1 DIMMER1 OUTPUT VOLTAGE 0V 10V 0V COMMON ANALOGUE OUTPUT1 DIMMER1 Nº 6 ANALOGUE OUTPUT1 DIMMER1 E OUTPUT VOLTAGE 0V 10V 0 100 DO NOT CONNECT DO NOT CONNECT DO NOT CONNECT MENU ESC NEXT TEST OK RESET M Self Reclosing WORKING True RMS UNIVERSAL 5PM Consult Manual I N 30 mA 1000 mA 5 10 I N I N I N t 20 mS 1000 mS 230 23 V1 229 42V2 231 31 ...

Page 33: ...Ethernet cable 2 Go to Control panel Network connections or Network central and shared resources 3 Disable Wireless network connections and enable Local area connection should it be necessary 4 Click on Local area connection to open up the properties 5 Double click on Internet protocol TCP IP 6 Select Use the following IP address 7 Fill in the boxes as shown below Accept Windows XP 8 Open the brow...

Page 34: ...UNIVERSAL 7WR 1PHAD 34 Windows 7 ...

Page 35: ...nter Remote access configuration Execute the steps described in the previous section Internet Intranet connection configuration In order to access the WebServer remotely from any other network certain changes must be effected in the Router in the network where the WebServer is connected Since one is accessing remotely one cannot use the WebServer IP as if it were in the same physical network The r...

Page 36: ...for another belonging to the network To connect the unit up to the network s router or switch With 230V AC connect an RJ 45 cable from the unit to the router or switch From any PC in the network proceed as follows To obtain the network s parameters Go to start up Execute Type cmd exe Press Accept The screen goes black the so called command prompt The ipconfig exe command can now be used to see the...

Page 37: ...in the same network it is obligatory to configure different ports Please refer to More than one WebServer in the same network and Remote access configuration Display font size and type These parameters do not depend on the WebServer Should one wish to modify the letter size or font one must consult one s navigator Optimum display screen resolution 1280x1024 text size small or medium Help FAQ frequ...

Page 38: ...el PIN y por tanto la seguridad o privacidad del equipo está comprometida Atención PIN de usuario incorrecto Este aviso de error ocurre cuando el usuario pulsa cualquier botón Guardar Poner a 0 Enviar de las paginas Web al no haber introducido el PIN de usuario en la casilla justo al lado de dicho botón o al haber introducido un PIN erróneo CHAPTER 8 TECHNICAL SERVICE AUTHORIZED TECHNICAL SERVICE ...

Page 39: ... is guaranteed against any defect of manufacture or original components as determined by our Technical Service Any repair or substitution does not extend the guarantee period The guarantee covers Reception of the unit for its repair or servicing Cost of all components replacements and labour on original components The guarantee does not cover Transport Breakdown caused by non original components o...

Page 40: ...E 08302 MATARO Barcelona ESPAÑA www safeline es safeline safeline es R D Comercial Factory Administration T 34 93 8841820 T 34 93 7630801 T 34 93 7630671 T 34 93 8841821 F 34 93 7630090 F 34 93 7630090 comercial safeline es inves safeline es admin safeline es Made in EU ...