SafeGuard Compass User Manual Download Page 14

[email protected]

(208) 773-9263

A Product of

All rights reserved © 2018

Limited Warranty and Limitation of Liability

Effective November 1, 2017, this warranty applies to all products manufactured and sold by Safeguard Equipment, Inc. (the “Products”).
NOTICE: READ THIS LIMITATION OF WARRANTY AND LIABILITY BEFORE BUYING OR USING THE PRODUCTS CONTAINED 

HEREIN.
It is impossible to eliminate all risks associated with the use of the Products. Risks of serious injury or death, including risks associated with 

electrocution, arcing and thermal burns, are inherent in work in and around energized electrical systems. Such risks arise from the wide variety 

of electrical systems and equipment to which Products may be applied, the manner of use or application, weather and environmental conditions 

and/or other unknown factors, all of which are beyond the control of Safeguard Equipment, Inc. Safeguard Equipment, Inc. does not agree to be 

an insurer of these or other risks, and shall have no liability for any claims arising from these or other risks inherent in electrical systems.
WHEN YOU BUY OR USE THESE PRODUCTS, YOU AGREE TO ACCEPT THESE RISKS.
Safeguard Equipment, Inc. warrants to the original purchaser that the Products will be free from defects in material and workmanship under 

normal, with regular service and preventative maintenance, for a period of one (1) year from the date of shipment (the “Warranty Period”). 

Should any failure to conform with this warranty be found during the Warranty Period, you must notify Safeguard Equipment, Inc. of your 

claim within thirty (30) days of discovery, and within the Warranty Period. Your failure to give notice of claims of breach of warranty within 

the Warranty Period shall be deemed an absolute and unconditional waiver of claims for such defects. Safeguard Equipment, Inc. will have no 

responsibility to honor claims received after the date the applicable Warranty Period expires.
Upon notice of your claim, Safeguard Equipment, Inc. will provide a return authorization number and further instructions on how to return the 

product for service. You must follow Safeguard Equipment, Inc.’s instruction. You are responsible for all Product removal, handling, re-installation, 

and shipping (both to and from Safeguard Equipment, Inc.). Products returned for repair, as well as repaired or replacement Products, shall be 

sent postage / freight prepaid. After receipt of a product that Safeguard Equipment, Inc. determines is defective, Safeguard Equipment, Inc. 

will, at its option, either (1) repair (or authorize the repair of) the Product or (2) replace the Product, subject to the following: The Products are 

made using parts sourced from a variety of manufacturers. Due to the rapidly changing technology environment, parts may become obsolete / 

unavailable over time (end of life). In the event that a Product cannot be repaired or replaced due to unavailability of parts, Safeguard Equipment, 

Inc. will use commercially reasonable efforts to obtain substitute parts or conduct work around design, but cannot guarantee its ability to do so.
Items not found defective will be returned at your expense, or failing receipt of instruction from you on return of such items within five (5) 

business days of our notice to you that the product is not defective, Safeguard Equipment, Inc. may dispose of the product at its discretion and 

with no liability to you. Safeguard Equipment, Inc.’s determination of defects is final. Products repaired or replaced during the Warranty Period 

shall be covered by the foregoing warranties for the remainder of the original Warranty Period or ninety (90) days from the date of delivery of the 

repaired or replaced Products, whichever is longer.
LIMITATIONS
•  This warranty is void in the event of misuse, alteration, faulty installation, or misapplication of the product.

•  This warranty does not cover failure of product or components due to any ACT OF NATURE, including, but not limited to, lightning, floods, 

hurricanes, tornadoes or any other such catastrophic events.

•  Safeguard Equipment, Inc. does not warrant any third party products or associated hardware or their performance or suitability for use and 

application.

•  All repairs must be authorized by Safeguard Equipment, Inc. Unauthorized repairs will not be reimbursed under any circumstances.

•  Safeguard Equipment, Inc. is not required to make replacement or loaner equipment available while Products are being repaired or replaced, 

or to compensate you for any in/out labor charges or expenses associated with removal, handling or re-installation of the products.

To the maximum extent permitted by law, this warranty and the remedies set forth above are exclusive and in lieu of all other warranties,

remedies and conditions, whether oral or written, express or implied.
SAFEGUARD EQUIPMENT, INC. EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, 

INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY 

AND NON-INFRINGEMENT.
IN NO EVENT SHALL SAFEGUARD EQUIPMENT, INC. BE LIABLE FOR ANY INDIRECT, INCIDENTAL, CONSEQUENTIAL OR 

SPECIAL DAMAGES RESULTING FROM THE USE OR HANDLING OF THESE PRODUCTS. THIS SHALL INCLUDE, BUT IS NOT 

LIMITED TO, LOST PROFITS OR REVENUE, LOSS OF USE OF THE PRODUCTS, COST OF SUBSTITUTE PRODUCTS, FACILITIES OR 

SERVICES, OR DOWNTIME.
IN NO EVENT SHALL SAFEGUARD EQUIPMENT, INC. HAVE ANY LIABILITY FOR ANY THIRD PARTY PRODUCTS OR ASSOCIATED 

HARDWARE, OR CUSTOMER-OWNED SYSTEMS, EQUIPMENT OR SOFTWARE.
-Safeguard Equipment, Inc. must have prompt notice of any claim so that an immediate product inspection and investigation can be made. Buyer 

and all users shall promptly notify Safeguard Equipment, Inc. of any claims, whether based on contract, negligence, strict liability, or other tort 

or otherwise be barred from any remedy.

Summary of Contents for Compass

Page 1: ...Always on Always safe Always aware User Guide Personal Voltage Current Detector...

Page 2: ...around high voltage Overview Compass is a non contact high voltage detector that alerts users when they approach an electrified source Its advanced notification system is designed to warn the user of...

Page 3: ...ields but will NOT fully block magnetic fields Conductors lying on the ground or very close to it will result in unsafe warning distances Electric fields will couple to the ground thus drastically red...

Page 4: ...ugged from the charger Compass briefly displays the pre set sensitivity level before activating full function of the device Compass should be worn on the underside brim of the user s hard hat and with...

Page 5: ...hes this level and will continue until battery is dead Master Sensitivity Settings FOR MANAGEMENT ONLY Plug device into the micro USB to begin charging then hold the center button for 5 seconds Red li...

Page 6: ...hts indicating the adjustable AC VOLTAGE menu Once you are in this menu display quickly press the center button to change the device s sensitivity to Low 3 lights Medium 5 lights High 7 lights or Adap...

Page 7: ...on or near the ground the warning distances will be dramatically reduced and can sometimes result in unsafe warning distances 20 ft 0 ft Busbar First Alert 12 ft Max Alert 6 ft 2 4 kV Proximity Alert...

Page 8: ...vity level provided by Compass It is important to note that these established ranges fluctuate slightly due to a variety of work environment variables Potential variables include but are not limited t...

Page 9: ...ectional notifications it s important to understand potential variables that could affect the accuracy of alerts Accuracy of directional alerts will be reduced when an overhead power system is above t...

Page 10: ...t environment without the unit continuing to emit alerts If the user stays in place no further alerts will be emitted Should the user move closer to the threat the COMPASS will again initiate alerts A...

Page 11: ...ed 2018 General Warning Distances 5 10 15 20 25 5 10 15 20 25 5 15 20 25 10 Side View First Alert Full Alert Sensitivity Setting HIGH Voltage 2 4 kV Sensitivity Setting HIGH Voltage 2 4 kV 0 0 5 5 10...

Page 12: ...en proximity to a computer or other such device can sometimes cause the COMPASS to lock the user out If this happens please see the instructions below on how to reset the device if this should happen...

Page 13: ...djustable Sensitivity Levels Low Medium High Adaptive Default Sensitivity Level High Operating Frequency 60 Hz Operating Voltages 2400 VAC Minimum to 35 4 kVAC RMS Line to Neutral Case Material Flame...

Page 14: ...f life In the event that a Product cannot be repaired or replaced due to unavailability of parts Safeguard Equipment Inc will use commercially reasonable efforts to obtain substitute parts or conduct...

Page 15: ...UIPMENT COM 208 773 9263 A Product of All rights reserved 2018 Contact Information www safeguardequipment com sales safeguardequipment com Phone 208 773 9263 Address 4442 West Riverbend Avenue Post Fa...

Reviews: