background image

TECHNICAL SUPPORT

If you encounter any difficulty in the operation of this product 

after 

r

eading the 

m

anual, please contact us. You can reach us by phone at 

904-245-1184

 from 8:

0

0 AM to 5:00 PM Monday through Friday (

Eastern

Standard Time). We will be happy to answer your questions and help you 

in any way we can.

WARRANTY

Safeguard Supply

 warrants this product to be free of defects in 

material 

and 

workmanship for a period of one year from the date of purchase.  This warranty 

does not cover damage resulting from accident, abuse, act of god or improper 

operation. If this product does  become defective, simply return it to 

Safeguard 

Supply

. Please include a note describing the troubles along with your name and 

return address as well as the original sales receipt. If the product is  covered under 

warranty it will be repaired or replaced at no charge. If it is not covered by 

warranty, you will be notified of any charges before work is done.

Safeguard Supply

 - www.safeguardsupply.com

2260 Moon Station Ct. NW #110

 , 

Kennesaw, GA 30144

Phone: (

678

214

-

4212

Mounting the 

T

ransmitter

:

 

The PIR sensor (transmitter) may be mounted in a variety of

locations such as; on the ceiling, directly above the door, or

side

 

mounted.  The most common mounting location is above

the

 

door.

For best results, mount the transmitter above the door frame

slightly canted in towards the door.  You may cant (tilt) the unit

to

 

ensure the monitored zone is covering the area you want it

to

 

cover.

Avoid placing the transmitter near heating & A/C ducts, or in

direct

 

sunlight to help eliminate false signals.

The mounting height of the sensor (see table 1) changes the

size

 

of the monitored zone.

WARNING:

 Cancer and Reproductive Harm. Go to 

www.P65Warnings.ca.gov

 

for

 

more information.

Volume

 Adjustment

:

The  volume  is  also  controlled  by  the  "volume  control  and 

tone  selector  button."    To  change  the  volume  level,  make 

sure the unit is not in program mode. Ensure the RED LED IS 

NOT  lighted  (Lighted  RED  LED  means  the  unit  is  in 

programming mode.) 

1.

The sensor has four volume levels.  By default the unit is set

to volume 4, the highest volume level.

2.

To adjust the volume, press the "volume control and tone

selector" button until the desired volume level is reached

(see

 

figure 2)

.

3. After a

djusting the volume, reassemble the unit.

1. Use included screw to mount the metallic bracket.  We

recommend mounting the bracket so that the openings on each

end of the bracket are facing up (shaped liked a "U").

2.

Each side of the transmitter has a screw protruding.  That screw

slides into the u-shaped openings of the bracket.

3.

Insert the unit into the bracket.  Each screw on the side

s

 of the

sensor

 should rest on open ends of the u-shaped bracket.

4.

Tighten the screws on the side of the case just enough to keep it

 

in

place (do not let it fall out)

.

5.

Tilt sensor in bracket to create desired monitored zone and test.

6.

Tighten the screws on each side of the case to secure it to the

bracket.

Table 1

*

Height of Sensor 

(in f

eet

)

 Change

s

 

the 

Width and Depth of 

Monitored Zone

.

Height 

Width 

Depth 

8’ 

9.20’ 

0.60’ 

10’ 

11.5’ 

0.75’ 

13’ 

14.95’ 

0.98’ 

16’ 

18.40’ 

1.20’ 

Reviews: