TECHNICAL SPECIFIKATION

FEATURE DESCRIPTION

• 

Lock case (scandinavian module)

• 

Built-in logic for motor control and indications.

• 

Indication of "Bolt out" and "door closed".

• 

Potential free connection for activation.

Power Supply

Continuous voltage between red and green wire 12-24 Vdc + - 10% required for lock to operate

Activate

To unlock, a potential free connection between yellow and black

cable requires and door magnet is activated.

When bolt reached its inner position it changes status of the bolt indicator.

A closed circuit (from eg. acces control) unlocks the lock and after

three seconds bolt locks out. A constant connection works as

day blocking and keeps bolt unlocked until the connection breaks. (eg clock).

Thumb turn / Cylinder

For manual activation with knobs or key bolt must reach

inner position within three seconds for a valid activation.

Three seconds delay before bolt is locked out.

Locking

After a valid activation,door magnet must be detected before

bolt runs out and locks the door, and bolt indicator change status.

Blocking

When bolt is blocked, the current movement stops and bolt

switches position, after two seconds, another attempt to lock will start.

Bolt-position indicator switches status when blocking has been eliminated

and bolt has reached its correct position.

Manipulation

If the bolt, without a valid activation, loses contact with the "bolt out" sensor,

an attempt to lock will be made. If bolt is blocked,

the relay changes status to "Bolt in", while

further attempt to lock is implemented.

Only when bolt reaches outer position or get a valid activation,

this procedure will stop.

Summary of Contents for ML 128

Page 1: ...MANUAL SAFETRON ML 128 135 ML 151 152 2 0 1 5 0 9 2 2 1 5 2 1 5 1 SE S 2 6 S 7 12 EN 1 3 5 1 2 8 ...

Page 2: ...r Vred Cylinder Vid manuell aktivering med vred eller nyckel måste kolven nå inneläget inom tre sekunder för giltig aktivering Därefter är det en fördröjning på tre sekunder innan kolven låses ut Låsa Efter en giltig aktivering måste dörrmagneten kännas av innan kolven går ut och låser dörren och ändrar status på kolv indikeringen Blockering När kolven blir blockerad avbryts den pågående rörelsen ...

Page 3: ...el av typ data tele signal enkelledare med areor mellan 0 1 0 2 får inte användas som spänningsmatning av låset Safetron ger ingen funktionsgaranti på installationer som inte följer rekommendationer Rekommenderad minsta kabelarea mellan spänningskälla trafo ej passage system styrenhet låshus totallängd O B S Det är viktigt att strömförsörjningen till styrenheten har rätt dimensionerad kabel för at...

Page 4: ...VDC Standby 15 Motordrift 100 Blockerad 200 10 30 VDC 8 24 VAC inga krav beträffande polaritet 60V 0 2A För frånreglingstid Under 0 3 sekunder SE ml 151 Modell ML 151 ML 152 Vid montering av låshus och cylinder ska långa urtaget i cylinderroddaren peka uppåt på båda sidorna Modell ML 128 ML 135 Vid montering av låshus och cylinder ska långa urtaget i cylinderroddaren peka mot stolpen på låskistan ...

Page 5: ...MÅTTRITNINGAR Montering låskista ML 151 ML 152 ML 128 ML 135 50 20 42 42 111 170 R11 22 225 200 R16 50 3 140 28 40 27 220 23 138 41 30 176 59 26 28 35 13 50 20 16 6 58 120 50 10 SE ...

Page 6: ...ERING TRYCKE OCH VRED SE Orange Grå Röd Svart Grön Vit Lila 12 24Vac dc 12 24Vac dc Aktivering med potentialfri slutning NC Dörr stängd Gul NC Regel ute Brun Svart och brun kabel byglas för kolv inne funktion NC Regel inne ...

Page 7: ...ks eg clock Thumb turn Cylinder For manual activation with knobs or key bolt must reach inner position within three seconds for a valid activation Three seconds delay before bolt is locked out Locking After a valid activation door magnet must be detected before bolt runs out and locks the door and bolt indicator change status Blocking When bolt is blocked the current movement stops and bolt switch...

Page 8: ...tandby 15 Motor active 100 Blocked 200 10 30 VDC 8 24 VAC no polarity requirements 60V 0 2A Unlocking locking time Under 0 3 sec EN ml 151 ML 151 ML 152 ML 128 ML 135 Modell ML 151 ML 152 Mounting the cylinder on lock case Arrow shall point upp on both sides Modell ML 128 ML 135 Mounting the cylinder on lock case Arrow shall point at face plate on both sides Art nr Accessories Cable 6m Cable 10m S...

Page 9: ...ers and the like the total power consumption is taken into account when calculating the cable area Cable length 12 24 VDC 0 10m 0 17mm 11 20m 0 34mm 21 40m 0 68mm 61 80m 1 36mm 81 100m 1 7mm RECOMMENDATIONS WHEN INSTALLING MOTOR LOCKS Recommendations when installing motor locks Read and follow the installation instructions In cases where double cylinder is not used a magnetic thumb turn should be ...

Page 10: ...DIMENSIONS Lock case Installation ML 151 ML 152 ML 128 ML 135 50 20 42 42 111 170 R11 22 225 200 R16 50 3 140 28 40 27 220 23 138 41 30 176 59 26 28 35 13 50 20 16 6 58 120 50 10 EN ...

Page 11: ...ON OF DOOR HANDLE AND THUMB TURN EN Orange Grey Red Black Green White Purple 12 24Vac dc 12 24Vac dc Activating NC door closed Yellow NC Bolt out Brown Shorten black and brown for reversed function on bolt indication NC Bolt in ...

Page 12: ... EGNA ANTECKNINGAR ...

Page 13: ... EGNA ANTECKNINGAR ...

Page 14: ...lattor Låshusets elektriska delar är underhållsfria Kontrollera och justera vid behov att dörren stängs korrekt För att uppnå detta kan t ex dörrens gångjärn liksom dörrstängare behöva justeras En dålig dörrfunktion påverkar låsfunktionen negativt MAINTENANCE SAFETRON MOTOR LOCK Maintenance should be performed by a trained professional Ensure that mounted knobs handles and cylinders are working sa...

Page 15: ...Safetron AB Box 2096 Säterivägen 18 65002 Karlstad Tel 46 0 54 19 02 45 Mail info safetron com Internet www safetron com ...

Reviews: