13
ERROR MENU
The control unit logs all errors in menu 21 which is found in the display of the
control unit.
Example
07:43:21 32
1
Time of error
Error
code
ID
ERROR LOG (MENU 21)
Errors that require immediate attention. Error diod is lit when errors are present in the log
NO
ERROR
DESCRIPTION
10
PD Disconnected
Lock disconnected from the BUS
20
Overcurrent
Overcurrent on TCBUS-output. Max: 1.2A. Also could suggest short circuit
21
Low voltage
Triggered below 11V
22
High voltage
Triggered above 50V
23
Low humidity
Triggered below 4%
24
High humidity
Triggered above 90%
25
Low temperature
Triggered below -20°C
26
High temperature
Triggered above 70°C
NO
ERROR
DESCRIPTION
31
Bolt blocked
Id is the adress of lock case
32
Door larm
Door open longer than set max time
33
Manipulation
Bolt manipulation. Triggered when bolt looses in/out status