INSTALLATION INSTRUCTIONS 

 

Follow these instructions carefully. Failure to follow these instructions can 
damage the unit and void the warranty. 

 

Important: The 70 Series case requires 1 1/2” (38mm) clearance.  
 
MODEL  70-742  

1.

 

Basic Model 70-742

 - Select a wall location between 4” and 20” off the 

floor.  Cut a 5 5/8” (143mm) W x 3 1/8” (79mm) H hole.  

2.

 

Connect Supply (+) to the Red wire lead.  Install a 1 amp fuse in the 
positive (+) circuit. Connect the Black wire to the 12 volt Ground (-). 

3.

 

Reconnect the power supply. Warm up 10 minutes then test the alarm. 

 

 

 
MODEL  70-742-R KIT    

1.

 

Model 70-742-R Kit - With Normally Closed relay.

 This unit supplies 

a relay with contacts rated 12 VDC, 3 amp (max). The relay is energized 
whenever the alarm is operational. It may be used to shut down a 
generator or to open an (optional) gas solenoid valve. The relay may also 
be used to interface to alarm systems, using either the normally closed or 
normally open contact, depending on the requirements of the alarm 
system. In the event of an alarm the relay will shut off.  It will 
automatically energize after the unsafe levels of CO or explosive gas 
clears.  
Select a wall location between 4” and 20” off the floor. Cut a 5 5/8” 
(143mm) W x 3 1/8” (79mm) H hole. 

2.

 

 Mount the solenoid according to its separate instructions. You must 
install the solenoid included with the 70-742-R-Kit

. Do not connect 

to an existing installed solenoid.

 

SEE: SPECIAL WIRING 

NOTICE. 

Connect the Red wire and either White wire from the alarm to 

the 12 volt supply (+). Install a 5 amp fuse in the positive (+) circuit 
between this connection and the battery.  
Connect the Black wire to the 12 volt Ground (-). 

3.

 

Relay Output – Connect the remaining White wire from the alarm to 
either black wire from the solenoid. 
 Ground the remaining Black wire from the solenoid to the negative side 
(-) of the 12 volt battery OR ground it to the RV Chassis.  
Note: Some devices do not require correct polarity and can be connected 
to either terminal or wire. 

4.

 

Reconnect the power supply. Warm up 10 minutes then test the alarm. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIAL WIRING NOTICE:

 When replacing CCI Controls LP Gas 

Leak Detectors they may have two power leads. Safe-T-Alert units only 
have one power lead. Simply connect the Safe-T-Alert power lead (Red) to 
the coach/house power supply and cap or remove the other power lead. 

DO 

NOT CONNECT BOTH POWER LEADS TO THE Safe-T-Alert 
ALARM – this will result in a dead chassis battery.

  

 

Only use UL or recognized permanent wire connectors to 
replace any unit installed with spade connectors or wire nuts.

 

  

TEST PROCEDURE

 

!

 WARNING 

TO  REDUCE  THE  RISK  OF  CARBON  MONOXIDE  POISONING 
OR  PROPANE  GAS  EXPLOSION,  TEST  THIS  ALARM’S 
OPERATION AFTER THE RV HAS BEEN IN STORAGE, BEFORE 
EACH TRIP AND AT LEAST ONCE PER WEEK DURING USE BY 
PRESSING THE TEST/RESET BUTTON

!

 

WARNING 

WARNING:  THE  TEST  BUTTON  ONLY  TESTS  THE 
ALARM  CIRCUIT  NOT  THE  SENSORS.  YOU  MAY  USE 
PROPANE OR BUTANE GAS TO TEST THE GAS SENSOR. 
Note it may take up to 10 seconds for the alarm to sound. 
TO TEST THE CO SENSOR USE A CAN OF SAFE-T-ALERT 
CO  TEST  GAS  TO  TEST  THE  400  PPM  CALABRATION 
POINT.  DO  NOT  TRY  TO  GENERATE  CO  TO  TEST  THE 
ALARM.

  The TEST/RESET button tests all ELECTRICAL functions of 

the alarm. It does not check the sensor operation. 

The alarm may be tested at any time. The TEST/Mute switch is located on 
the  front  of  the  alarm.  Press  and  hold  the  test  button  for  1  second 

IMPORTANT

 - 

 If this alarm does not test properly return it immediately 

for repair or replacement. If the alarm is over five years old replace it. 

 

OPERATION

 

 When the unit is first powered up, the CO sensor requires a ten (10) minute 
initial warm-up period to clean the sensor element and achieve stabilization. 
The  GREEN  LED  indicator  will  flash  on  and  off  during  the  10  minute 
warm-up  period.  This  unit  cannot  go  into  a  alarm  during  the  warm-up 
period.  See Test Procedure in this manual.  After the warm-up period, the 
GREEN power ON indicator should glow continuously

 

If the ON indicator 

light  does  not  light,  see  the  section, 

Trouble-Shooting  Guide

,  in  this 

manual for further information.  

Do not attempt to fix it yourself. 

Gas  Alarm: 

When  you  power  the  alarm,  it  has  a  warm-up  period  of 

approximately  1  minute.  This  unit  cannot  go  into  a  gas  alarm  during  the 
warm-up period.  After 1 minute the alarm can detect explosive gas and will 
energize the relay on model 70-742-R-Kit.  

Simultaneous  CO  and  Gas  Alarms—

  Because  the  risk  of  a  propane  gas 

explosion is generally a more serious danger, your alarm unit gives the gas 
alarm a higher priority during simultaneous alarm condition.

 

If your unit generates alarms for both Gas and CO at the same time, the gas 
LED  will flash red and the beeper will sound.  The CO LED will be a solid 
Red  until  the  CO  is  ventilated  out  of  the  RV,  at  which  time  the  LED  will 
return to the Green operational/safe color.   

!

 DANAGER - FIRE RISK - CCI CONTROLS GAS 

LEAK DETECTOR REPLACEMENT   

      - DO NOT CONNECT A SAFE-T-ALERT alarm to non 

Safe-T-Alert supplied solenoid. You must use the new 
solenoid included in your Kit.  DO NOT CONNECT TO 
A CCI SOLENOID. 

 