6 COMMUNICATION

RED

BLUE

GREEN

•  When the S-Bridge is connected to an host waiting for a 

connection with a Safe Spacer, its LED will turn green.

RED

BLUE

GREEN

  

•  When a Safe Spacer is connected to the S-Bridge, both the units 

are light up blue.

GREEN

  

GREEN

BLUE

  

•  Once the connection is terminated and the data are transferred 

successfully, the Safe Spacer will blink green and a single 

vibration occurs. Then the Safe Spacer will restart and the lights 

will blink green/blue alternatively for 10 seconds.

•  Once the connection is terminated and the data are transferred 

successfully, the S-Bridge will blink green.

8

Summary of Contents for S-Bridge

Page 1: ...Wearable social distance monitor S Bridge...

Page 2: ...OF CONTENTS 1 SAFETY INSTRUCTIONS 3 1 1 Repair and modifications 3 2 OVERVIEW 4 3 WALL MOUNTING 5 4 INSTALLATION 6 5 CONNECTION AND DATA TRANSFER 7 6 COMMUNICATION 8 7 SPECS 10 S Bridge 10 REGULATORY...

Page 3: ...distance of separation between your medical device and S Bridge If you suspect S Bridge is interfering with your medical device stop using it immediately and consult your physician NOT FOR USE IN A P...

Page 4: ...2 OVERVIEW SCREW HOLE MICRO USB PORT TO IK141 101 MICRO USB PORT MICRO USB PORT TO HOST LED LIGHTS 4...

Page 5: ...3 WALL MOUNTING Mount the holder to the wall using the included screw and wall anchor Tighten the screw to fasten the holder to the wall 5...

Page 6: ...4 INSTALLATION Insert the device IK141 101 into the holder paying attention to the position of the Micro USB connector 6...

Page 7: ...ND DATA TRANSFER Plug the Micro USB to USB A cable to the Micro USB port located in the bottom side of the holder Use the other end of the cable to connect the unit to computer or IT infrastructure MI...

Page 8: ...oth the units are light up blue GREEN GREEN BLUE Once the connection is terminated and the data are transferred successfully the Safe Spacer will blink green and a single vibration occurs Then the Saf...

Page 9: ...RED BLUE GREEN If the connection is terminated with issues both the Safe Spacer and S Bridge will blink red If this occurs try again until the connection will end successfully 9...

Page 10: ...humidity Storage 20 C to 55 C 0 to 98 relative humidity Certification FCC IC CE CE RED Casing Material PA polyamide Wall Holder Material PP Polypropylene USB cable Micro USB male to USB A male cable...

Page 11: ...2 This device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance c...

Reviews: