INTEGRA-X User Manual
WEB GUI
SAF Tehnika JSC
22
Ethernet management connection configuration
Before proceeding with the initial link setup in the Web GUI, you must adjust the IPv4 settings
of your LAN adapter to 192.168.205.0 subnet (see
Figure 3-3 LAN adapter setup for example
).
The IP address should be something other than the default low/high side IP addresses
(192.168.205.10/192.168.205.11).
After applying these settings you are ready to connect to the Web GUI or establish an
SSH/Telnet connection. Refer to
Chapter 4: COMMAND LINE INTERFACE
for the details on how
to connect to other CLI interfaces (serial, SSH, Telnet).
Accessing Web GUI
1) Launch your browser and in the address field enter the IP address of a FODU. Default IP
addresses are as follows:
192.168.205.10 for low side FODU (P/N D11XS***L*)
192.168.205.11 for high side FODU (P/N D11XS***H*)
For secure connection use
https://
prefix.
2)
Press “Enter” key.
Figure 3-3 LAN adapter setup
Figure 3-4 Browser’s address field