GENERAL: 

This Back-Leg-Chest Dynamometer is designed to accurately measure the isometric force 

produced by musculature of the back, leg, chest and shoulders. This device allows medical 

staff to test a patient’s fitness status and to carry out controlled training during the 

rehabilitation process. The appliance should be checked for correct condition prior to each 

usage by a person familiar with proper operation of the balance. 

 

INFORMATION ON COMPONENTS, PACKAGE CONTENT :   

 

 

 

No. 

Name 

Function 

Body 

All-metal construction 

Dial 

Scale measures up to 300 kg (660 lbs) 

Pointer 

The pointer on the dial indicates the force exerted. 

Footstand 

Stable base for footing 

Hand grip 

Contoured handles for solid grip   

Subject should lift in a gradual vertical motion. 

Chain 

Chain length is adjusted to accommodate for height 

differences or to vary the point of force application 

Summary of Contents for SH5007

Page 1: ...BACK LEG CHEST DYNAMOMETER SH5007 User Manual...

Page 2: ...liance should be checked for correct condition prior to each usage by a person familiar with proper operation of the balance INFORMATION ON COMPONENTS PACKAGE CONTENT No Name Function 1 Body All metal...

Page 3: ...device in areas of high temperature especially in places near heating equipment in moist or dusty places or where it will be directly exposed to water If the device is dirty wipe it with a soft dry cl...

Page 4: ...dy This insures that it does not interfere with the movement of the Pointer during the trial 1 Arm Lift 2 Torso Lift 3 Leg Lift 4 High Far Lift 5 Floor Lift 6 High Near Lift 3 Have the subject hold th...

Page 5: ......

Page 6: ...it s design are not permitted This may lead to incorrect measuring results safety related faults and destruction of the device The device may only be operated in accordance with the described default...

Page 7: ...y rooms doctors offices and patients rooms etc Equipment can be damaged when dropped to the floor Impossible to expect to work properly any more If it works properly calibration exactitude should be m...

Page 8: ...f the location where the appliance is used Warranty Warranty claims shall be voided in case Our conditions in the operation manual are ignored The appliance is used outside the described uses The appl...

Page 9: ...de Catalogue number Caution Fragile handle with care Keep dry Keep away from sunlight Consult instructions for use If there has been occurred any serious accident in relation to the our device release...

Page 10: ...amgongdan 13 gil Masanhoewon gu Changwon 51342 South Korea Phone 82 55 294 0381 Fax 82 55 293 5019 E mail saehancorp naver com Website www saehanmedical com MVS In Motion Westdijk 150 2830 Tisselt Bel...

Reviews: