Saeco International Group
Page 17 / 17
TALEA / ODEA - LINE
05 SERVICE MODALITY
5.4.
Error messages
Function group M3: Error log
The following will be displayed at this program level:
•
the last 20 faults
•
date when the fault occurred
CODE BRIEF DESCRIPTION
DESCRIPTION / POSSIBLE FAULT
FAULT IN THE COFFEE GRINDER
01
Coffee grinder blocked
No Hall sensor pulses:
•
Sensor/cable defective
•
Gearing mechanism defective
•
Coffee grinder blocked
•
The motor is not driven
BREWING UNIT FAULT
03
TORQUE_FAULT_FWD
Torque exceeded when moving to the brewing position
TIMEOUT_FWD
Time exceeded when moving to the brewing position
TIMEOUT_FWD_DOWN
Time exceeded when releasing the start position
microswitch
HOME_WHILE_WORKING
Activates the start position microswitch when moving
up to the brewing position
04
TORQUE_FAULT_RWD
Torque exceeded when returning to the start position
TIMEOUT_RWD
Time exceeded when returning to the start position
WORK_WHILE_HOMING
Activates the brewing position microswitch when mov-
ing to the start position
16
HOME_AND_WORK_PRESSED
Both gear microswitches operated at the same time
FAULT IN THE WATER CYCLE
05
No fl owmetre pulses when the
pump is activated
•
Flowmetre defective
•
Pump defective
•
Lead shifted
06
Hot water / steam valve vent
sensor board fault
More than one sensor is ON at the same time
FAULT WITH THE TEMPERATURE CONTROLLER
10
SENSOR1_SHORT
Short-circuit in the continuous-fl ow heater sensor
11
SENSOR1_OPEN
Interruption in the continuous-fl ow heater sensor
14
TEMPERATURE_BO_TOO_HIGH Temperature exceeded on the continuous-fl ow heater
15
TEMPERATURE_BO_OUT_CON-
TROL
Coffee boiler temperature controller is not working
(i.e. no response to signals: e.g. the continuous-fl ow
heater is switched on but the temperature does not
increase)
GENERAL FAULTS
19
No zero crossing
Power supply fault
20
Cup lift fault
Both limit switches operated at the same time
Summary of Contents for TALEA
Page 10: ...Saeco International Group Talea Odea Line CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 13: ...Saeco International Group Talea Odea Line CHAPTER 3 OPERATING...
Page 27: ...Saeco International Group Talea Odea Line CHAPTER 4 FUNCTIONAL PRINCIPLES...
Page 42: ...Saeco International Group Talea Odea Line CHAPTER 5 SERVICE MODALITY...
Page 77: ...CHAPTER 8 NOTES Saeco International Group Talea Odea Line...
Page 78: ...Saeco International Group Page 1 2 TALEA ODEA LINE 08 NOTES...
Page 79: ...Page 2 2 Saeco International Group 08 NOTES TALEA ODEA LINE...
Page 80: ...Saeco International Group Talea Odea Line CHAPTER 9 WATER SYSTEM DIAGRAMS...
Page 87: ...Saeco Internationa Group Talea Odea Line CHAPTER 10 WIRING DIAGRAMS...
Page 88: ...Odea Go...
Page 89: ......
Page 90: ...Odea Giro...
Page 91: ......
Page 92: ...Talea Giro Plus...
Page 93: ......
Page 94: ...Talea Ring...
Page 95: ......
Page 96: ...Talea Ring plus...
Page 97: ......
Page 98: ...Talea Touch Plus...
Page 99: ......