REV. 00 - Mar. 07
5.1.2 Microswitch and sensor check
Errors
(Errors)
Grounds drawer:
Grounds drawer micro
(Dregdraw:)
OK Drawer present
ER
drawer
missing
Service:
Door
microswitch
(Door:)
OK
door
closed
ER
door
open
Water tank:
Tank Micro
(WaTank:)
OK tank engaged
ER tank empty or in reserve (see diagnostics)
Water level:
Water level capacitive sensor
(WaLevel)
OK Water present
ER
Water
low
Drip. tray:
Drip tray capacitive sensor
(DripWater:)
OK drip tray empty
ER
drip
tray
full
milk tank:
Milk tank door micro
(MilkTank)
OK milk tank door closed
ER milk tank door open
Cappuccino valve:
Milk tank + cappuccino valve micro
(Milk Draw:)
OK milk tank and cappuccino valve inserted
ER milk tank and/or cappuccino valve not found
Drip. tray:
Drip tray micro
(no drip tray)
OK tray present
(Tray miss:)
ER no tray
Sensors
St: steam
Steam boiler temperature sensor (Touch Plus only)
Number:
current
temperature
OK Sensor connection ok
ER sensor shorted or disconnected
Wa: water
Water boiler temperature sensor
Number:
current
temperature
OK Sensor connection ok
ER sensor shorted or disconnected
Dregdraw:OK
Door:OK
WaTank:OK
WaLevel:OK
DripWater:OK
MilkTank:OK
Milk Draw:OK
Tray miss:OK
Errors
Sensor
St:100:OK
Wa:100:OK
3/20
PRIMEA 2007 Chapter 05
Summary of Contents for PRIMEA LINE 2007
Page 3: ...REV 00 Mar 07 CHAPTER 1 INTRODUCTION REV 00 PRIMEA 2007 Chapter 01 ...
Page 5: ...REV 00 Mar 07 CHAPTER 2 TECHNICAL DATA REV 00 PRIMEA 2007 Chapter 02 ...
Page 9: ...REV 00 Mar 07 CHAPTER 3 BRIEF INSTRUCTIONS REV 00 PRIMEA 2007 Chapter 03 ...
Page 15: ...REV 00 Mar 07 CHAPTER 4 DIAGRAMS REV 00 PRIMEA 2007 Chapter 04 ...
Page 16: ...REV 00 Mar 07 4 1 Wiring diagram 1 6 PRIMEA 2007 Chapter 04 Primea Touch Plus ...
Page 17: ...REV 00 Mar 07 Primea Touch 2 6 PRIMEA Chapter 04 ...
Page 18: ...REV 00 Mar 07 Primea Ring 3 6 PRIMEA Chapter 04 ...
Page 22: ...REV 00 Mar 07 CHAPTER 5 TROUBLESHOOTING REV 00 PRIMEA 2007 Chapter 05 ...
Page 43: ...REV 00 Mar 07 CHAPTER 6 OPERATING LOGIC REV 00 PRIMEA Chapter 05 ...
Page 53: ...REV 00 Mar 07 CHAPTER 7 COMPONENT ASSEMBLY AND DISASSEMBLY REV 00 PRIMEA 2007 Chapter 07 ...
Page 76: ...REV 00 Mar 07 CHAPTER 8 SERVICE SCHEDULE REV 00 PRIMEA 2007 Chapter 08 ...
Page 78: ...REV 00 Mar 07 CHAPTER 9 AMENDMENTS MADE TO TECHNICAL SERVICE MANUAL PRIMEA Chapter 09 REV 00 ...