- 1 -
Vario Pedestal 2-75
Manual
1
Safety instructions
->
Pneumatic column is under pressure of up to 12 bars
(174 psi)
->
If one of the column lids has been damaged there is a pos-
sibility of getting injured. Therefore only use the column
again after its repair by a service technician.
->
Don’t use the column before it isn’t correctly locked into the
dolly.
->
Never release the transport lock without a payload in place,
since the unloaded column will move up strongly. This may
cause injuries or damage.
->
Never push down column with “LOCK” or “DRAG” applied.
2 Characteristics
The Vario Ped 2-75 is a “true” two stage pedestals for OB
and studio applications. They have an extended “on-air”
stroke of 77 cm/30 inches.
Fig. 1
Steering wheel
Dolly
Cardan
Column
Quickfix
Trim weight
Cover lid