RELAY 1
RELAY 2
RELAY 3
RELAY 4
FUSE
POWER
TIMER
Timer Select Button
– Used to select timer mode
Erase Button
– Press and hold to erase all pairings, see
advanced operation for individual erase
Signal Test mode
– Press to enter signal test mode
Sync/Pair Button
– Press once to auto sync. See
Advanced operation for other pairing options.
Momentary/Latching Jumper Links
– It is possible to set
the relay switches on the ELITE receiver to either momentary
or latching operation.
Latching (link fitted)
- One press for on, one press for off.
Momentary (link removed)
- On while button is held only.
To set a relay switch to either momentary/latching choose the
associated link cap.
NOTE:
If link is changed, power cycle
the receiver (turn off/on) otherwise it will stay in the
same mode it was previously set in.
230Vac power
input
Power input fuse – should be 500mA
Relay switch terminals:
C
om
m
on
N
or
m
all
y
O
p
en
N
or
m
all
y
C
lo
se
d
RELAY 1
RELAY 2
RELAY 3
RELAY 4
SYNC
TEST
ERASE
Status LEDs
– Flash when
signals are sent/received
L N E
8
7
6
5
4
3
2
1
Mag sync
– Touch a
magnet to the plastic
case in the cross
hatched area to
replicate the sync
button on board
without opening the
case
0V
d
c
12
-3
2V
d
c
NO COM NC
NO COM NC
NO COM NC
NO COM NC
CONNECT EITHER
230Vac OR 12-32Vdc
NEVER BOTH
RELAY 1
RELAY 3
RELAY 4
FUSE
POWER
TIMER
RELAY 1
RELAY 2
RELAY 3
RELAY 4
SYNC
TEST
ERASE
L N E
8
7
6
5
4
3
2
1
0V
dc
12
-3
2V
ac
/d
c
NO COM NC
NO COM NC
NO COM NC
NO COM NC
CONNECT EITHER
230Vac OR 12-32Vac/dc
NEVER BOTH
230V INPUT
SUPPLY
A
C
D
B