REFER TO THE DIAGRAMS BELOW FOR THE FOLLOWING PROCEDURES
This manual covers the PT-6001 Power Tower installati on only. However, note that existi ng conduits
leading from each light locati on in the pool should be:
• made of non-metallic polymeric material (PVC), and
• all conduit joints must be waterti ght.
1. Conduit installati on. Refer to
Figure A
below for opti onal PT-Base
a) 120VAC input power conduit. This conduit should be installed so it protrudes through the smaller of
the two ports in PT-Base – located toward the front / right as pictured in
Figure A
below. It should at
least be fl ush with the port but extend no more than 1ʺ above it.
b) 12VAC output conduit. Cables from the lights must all come through the larger of the two ports in
the PT-Base as pictured in
Figure A
. This conduit should extend approximately halfway up into the
space below the port.
I N S TA L L AT I O N G U I D E L I N E S
Low Voltage
Terminals
12VAC Conduit Hole: At Least
12" of Free 12VAC Cord Should
Be Protruding Past Hole
Electrical Conduit Hole:
Electric Conduit Should
Protrude1" Or Less
Use Sweep Ells Or Heat
Bend For Gentle Radius
60W Transformer
(behind bracket)
Fuse location
w/ 6A Fuse
High Voltage
Terminals
RF Receiver & Antenna
Overview of internal component locati ons
FIGURE A: Opti onal part PT-BASE