S.R.Smith poolLUX Plus 1ML-pLX-PL60 Installation Instructions Manual Download Page 4

4

I M P O R TA N T   S A F E T Y   I N F O R M AT I O N

CAUTION: POWER AND SIGNAL OUTPUT CONDUITS MUST BE NON-METALLIC

ATTENTION: CONDUITS POUR PUISSANCE DE SORTIE ET SORTIE SIGNAL DOIT ETRE NON METALLIQUE

ELECTRICAL SHOCK HAZARD – SWITCH DOES NOT TURN OFF INPUT POWER.

Failure to disconnect input power before servicing can lead to serious injury, or death.
Disconnect input power before servicing.
Replace all parts and panels before reconnecting power and operating

DANGER – FAILURE TO FOLLOW THESE WARNINGS, INSTRUCTIONS, AND THE 
OWNER’S MANUAL MAY RESULT IN SERIOUS INJURY OR DEATH.

Basic safety precautions shall be observed when installing and operating the poolLUX

®

 Plus  

(p/n pLX-PL60/PL100) and other associated equipment:

1.  A qualified electrician must install the poolLUX

®

 Plus (p/n pLX-PL60/PL100) in accordance 

with the requirements of NEC ANSI/NFPA 70 and Article 680.

2.  The poolLUX

®

 Plus (p/n pLX-PL60/PL100) must be mounted on a flat vertical surface. The 

unit must be a minimum of 4 inches above the ground level, pool deck, or higher than 8 inches 
above the maximum pool water level, whichever provides greatest elevation.  The unit must be 
positioned a minimum of 4 feet (1.2 m) away from the inside wall of the pool, unless separated 
from the pool by a solid fence, wall, or other permanent barrier.

3.  CAUTION: THE EQUIPMENT AND CONTROLS SHALL BE LOCATED NOT LESS THAN  

1 M HORIZONTALLY FROM THE SPA OR HOT TUB.

4.  ATTENTION: MAINTENIR UNE DISTANCE MINIMALE, MESURÉE DANS UN PLAN 

HORIZONTAL, DE 1 M ENTRE LA CUVE DE RELAXATION ET LES APPAREILS ET 
COMMANDES.

5.  ONLY USE COPPER CONDUCTORS.

6.  Do not exceed the maximum electrical ratings of the poolLUX

®

 Plus (p/n pLX-PL60/PL100) 

components (indicated on page 6), wiring devices, and current carrying capacity of the 
conductors.

7.  poolLUX

®

 Plus (p/n pLX-PL60/PL100) is intended to be used with low voltage underwater 

luminaires that comply with Article 680 of the National Electrical Code and does not require 
bonding due to their polymeric or isolated application design.

8.  This device should never operate equipment that could cause property damage, bodily injury, 

or death should it be activated unexpectedly.

9.  Use with branch circuit breakers with 15 amperes or less.

10.  This device must be used with an approved ground-fault circuit interrupter (GFCI). 

11.  Use rain-tight or wet location hubs that comply with the requirements in the standard (UL514b) 

for conduit, tubing, and cable fittings only.

12.  The conduit hub is to be connected to the power input conduit before the hub is connected to 

the enclosure.

13.  Never allow children to operate the pLX-Plus unit unsupervised.

Summary of Contents for poolLUX Plus 1ML-pLX-PL60

Page 1: ...on Instructions Read all instructions before attempting to perform installation work Type 3R Rainproof Enclosure FOR USE WITH POOL AND SPA PRODUCTS 5005508 ETL LISTED Conforms to UL STD 379 Certified...

Page 2: ...2...

Page 3: ...rical Ratings 6 Recommended Tools and Supplies 6 INSTALLATION INSTRUCTIONS 7 Enclosure mounting 7 Input Supply Line Voltage 9 Output Wiring for Lights and Light Sources 10 OPERATING INSTRUCTIONS 12 Ma...

Page 4: ...l of the pool unless separated from the pool by a solid fence wall or other permanent barrier 3 CAUTION THE EQUIPMENT AND CONTROLS SHALL BE LOCATED NOT LESS THAN 1 M HORIZONTALLY FROM THE SPA OR HOT T...

Page 5: ...nterference and 2 this device must accept any interference received including interference that may cause undesired operation 2 Changes or modifications not expressly approved by S R Smith LLC will vo...

Page 6: ...ernal Current Fuse and is designed to blow first in the event of a short and helps reduce whole transformer replacement due to field induced shorts sparking wires as well as other abnormal electrical...

Page 7: ...X Plus p n pLX PL60 PL100 in an appropriate area that meets the following requirements a Must be mounted on a flat vertical surface b Must be a minimum of 4 inches above the ground level pool deck or...

Page 8: ...y from the wall to allow the unit to be mounted correctly 4 Place the mounting tab of the poolLUX Plus p n pLX PL60 PL100 over the 10 screw and let it hang in place Level the unit and mark the remaini...

Page 9: ...conduits are connected replace the metal input voltage isolation barrier and mounting screw Tighten until the mounting screw is secure 2 Bring the supply power conduit to one of the four lower right...

Page 10: ...that the input wiring screw terminals are secure 12VAC 13VAC POWER INPUT NEUTRAL POWER INPUT POWER INPUT GROUND COM GROUND GND N H Input Wiring Locations O u t p u t W i r i n g f o r L i g h t s a n...

Page 11: ...tors to the electrical taps output terminals Most installations will utilize the terminal configuration of 12VAC terminal and low voltage common terminal In some cases additional voltage may be requir...

Page 12: ...ition To turn OFF the 12VAC connected lights flip the rocker switch to the DOWN to the OFF position To enable wireless control flip the rocker switch to the REMOTE position Color Changing Operation To...

Page 13: ...ent to the control panel To Turn On Using the Wireless Remote Wake the remote out of Sleep Mode press the 1 button to turn the system ON OFF Note The rocker switch on the poolLUX Plus must be set to R...

Page 14: ...BK BLACK B BLUE Y YELLOW G GROUND 2 ELECTRICAL CONNECTIONS LEGEND 12V 12VAC L V LOW VOLTAGE COMMON 13V 13VAC GND GROUND N POWER INPUT NEUTRAL H POWER INPUT 12VAC 13VAC POWER INPUT NEUTRAL POWER INPUT...

Page 15: ...15002 01 Isolation Barrier 02 15342 00 Isolation Barrier mounting screw 8 32 10 15078 05 Fuse Holder 36 15016 00 Fuse pLX PL60 36 15017 00 Fuse pLX PL100 36 15018 00 RF Receiver PCB 94 15262 00 RF Rem...

Page 16: ...P O Box 400 Canby OR 97013 P 503 266 2231 TF 800 824 4387 srsmith com 79 15264 00 REV6 18 Questions Contact One of Our Dedicated Lighting Specialists 1 800 824 4387 x4012 or x2282 2018 S R Smith All...

Reviews: