4>If only the lower limit value is not 0, the upper limit value is 
not 0, and the lower limit value is greater than the upper limit 
value, which means when the weighing data is greater than the 
lower limit value, or less than the upper limit value, the alarm is 
issued.   

4

  Counting operation 

During using

if you want to test the members

long press       

  for 3S more when in zero state

it shows cn0001 means   

  1 piece, press      to change and      to move, input same 

sample members

press      to confirm. 

wait for the data stabilization icon to appear, press       the 
button  to display the number of the value

then back to 

weighing state. 

5

  Pre-peeling operation 

Put object on scale, press            , it means reduced the package 

weight, when the weight is 0, the tare light will show up on the 

display, then put the weighed item into the package weight, and 

the weight value displayed at this time is the net weight of the 

item. After taking out the package and item, the weight value 

will be displayed as a negative number, and then press once 

6. Charging instruction 

When the battery is low, the “low voltage” indicator light is on. 

Please charge the battery for 12 hours before use. When 

charging, ac charging indicator shows “Red”, table shows in 

charging when full display “green”, can be in the display of 

green light. Continue charging for 3-4 hours to ensure sufficient 

battery power. 

7. Date/ / time setting 

Press      to open and wait it show 00.00.00,press      into 

Date/time setting ,the first one is years, press     to change, 

press       to move

press      after finish

then comes to 

second one is month, next one is day. Then press      to 

setting hours/minutes/seconds, same operation like below 

8.

 

Print item name switch 

In weighing 

long press       3S

it shows“P 000”      to 

change value

Such as

change to third name

press        to 

Summary of Contents for JL-168

Page 1: ...JL 168 Weighing Indicator Instruction No 601 Web WWW SKRSCALE COM Es JJF1624 2017 TEL 0592 5527990...

Page 2: ...low cockroaches and small creatures to enter the machine and cause damage 4 Do not hit or press do not exceed its maximum weight capacity 5 Remove the battery when it is not in use for a long time 6 W...

Page 3: ...er within setting range LO Weight or member lower setting range PCS Counting Model state kg Kilogram Unit g Gram Unit lb pound unit oz ounce unit AC Charge indication Low power Counting accumulation S...

Page 4: ...it value press to confirm Upper limit value setting longer press 3s in the state of weighing and into upper value setting it shows UP and 0 0 and flash press and to move then input upper value press t...

Page 5: ...weighed item into the package weight and the weight value displayed at this time is the net weight of the item After taking out the package and item the weight value will be displayed as a negative nu...

Page 6: ...a P03 Anti vibration coefficient setting P03 00 01 02 09 the greater the value the more stable the data P04 boot unit setup P04 00 means kg P04 01 means g P04 02 means lb P04 03 means oz P05 tri color...

Page 7: ...05 03 Voice volume setting 03 00 Small 03 01 Big P06 Serial port printer parameter Setting Long press to enter setting P06 00 Serial communication switch 00 00 Serial communication off 00 01 Serial co...

Page 8: ...01 ON P06 06 Printer Style 06 00 Ticket printer 06 01 Label printer P06 07 Internal format P06 08 Print Model 08 00 Manual printing 08 01 Cumulative print 08 02 Automatic printing 08 03 Qualified pri...

Page 9: ...utomatically 01 06 Highest state print automatically P07 02 Weight lock time setting 02 00 00 09 can be choose 00 means lock time 0s 01 means lock time 1s same as others recommend 05 P08 Cumulative se...

Page 10: ...to move Press to setting division it shows div X press to change 1 The representative scale value is 1 jump 2 The representative scale value is 2 jump 5 The representative scale value is 5 jump Press...

Page 11: ...sage remind Power saving mode Version Battery voltage is 6 31V Over loaded Out of display digit Technician parament A D Accuracy 1 30000 Input sensitivity 0 2 Microvolts degrees Input voltage range 2m...

Page 12: ...ll input E 2 Empty 3 Empty 4 Empty 5 Shielding wire 6 Load cell input E 7 Empty 8 Load cell output S 9 Load cell output S 2 Air terminal Pin Specification 1 Load cell input E 2 Load cell output S 3 Lo...

Reviews: