Accept line test
One test you
MUST
also perform is to disable the
Accept Line
on the
tester and insert big and small coins. All coins
MUST
be rejected
when the accept line if OFF. If it does not come out of the changer, it
means the return path of the changer is jammed. Test the coin return
lever as well.
Emptying the tube
Once the test completed, it is now time to empty the tubes you just
filled.
Press on
Payout
and then on the corresponding button (5¢, 10¢, 25¢,
100¢)to dispense from each tube. To dispense one coin from the
tube, press briefly on the corresponding button. To empty this tube,
press and hold the button and the process will start. To stop it, press
on STOP. If you want to empty all the tubes in a single operation,
press and hold the ALL button until the payout starts. Note that only
the coins that went to the tube during you test you will be paid out.
To empty the rest, you may need to use the buttons on the changer
itself.
Press STOP before unplugging the coin changer.
Once everything tested and cleaned, you can slip your coin changer
into a bag, write a short memo and put that changer on a shelf for
future use.