13
List of messages coming from an MDB Coin Changer
The first line of the display is for messages sent by the device. The
error message is sent only when the device is performing an action.
On stand-by, the device is always sending its type (i.e.
changer level
2
). If an error is detected, it will be visible on the first line of the dis-
play.
It can also be seen elsewhere depending on the nature of the error
reported. For example, a tube sensor error in a level 2 changer
would be seen on the first line, in the payout section, and in the status
as seen below:
The message
What it means…
Acceptor unplugged
The MDB changer cannot detect its coin ac-
ceptor. Check if correctly plugged. Coin ac-
ceptor may be defective.
Cannot detect
The vending tester cannot detect the coin
changer. Check for harness damages.
Check for unplugged harness inside coin
changer.
Changer was reset
This message can be seen upon power-up
and when the device is being re-initialize.
Defective changer
The tester detects the unit cannot be tested
because of a general failure inside the coin
changer. Send the unit to a service center.