MC1K
LINEAR GAMMA RESPONSE TO 1000 mR/HR
y x
The new ergonimoc MC1K is a handheld survey
meter using a built-in energy compensated GM
detector. It detects gamma and x-rays up to 1000
mR/hr over 4 selectable ranges. A beep sounds
and a count light flashes with each event detected.
Detector
Energy compensated halogen-quenched GM tube.
Operating Range
X1 position 0 - 1 mR/hr or 0 - .01 mSv/hr
X10 position 1 - 10 mR/hr or 0 - .1 mSv/hr
X100 position 5 - 100 mR/hr or 0 - 1 mSv/hr
X1000 position 50 - 1000 mR/hr or 0 - 10 mSv/hr
Accuracy
Typically ±15% of reading (Cs
137
)
Energy Sensitivity
Detects gamma and x-rays down to 40 keV.
Response is flat from 40 keV up.
Audio Indicator
Internally mounted beeper (can be turned
off for silent operation).
Anti-Saturation
Meter will hold at full scale in fields as high as 100
times the maximum reading.
P.O. Box 39, 436 Farm Rd. Summertown, TN 38483
1-800-293-5759 | Fax: 931-964-3564
www.seintl.com | [email protected]
INTERNATIONAL
®