background image

6 — English

ELECTRICAL

ELECTRICAL CONNECTION

This tool is powered by a precision built electric motor. It 
should be connected to a 

power supply that is 120 v, AC 

only (normal household current), 60 hz. Do not operate 
this tool on direct current (DC). A substantial voltage drop 
will cause a loss of power and the motor will overheat. If the 
saw does not operate when plugged into an outlet, double 
check the power supply.

SPEED AND WIRINg

The no-load speed of this tool is approximately 5,800 rpm. 
This speed is not constant and decreases under a load or 
with lower voltage. For voltage, the wiring in a shop is as 
important as the motor’s horsepower rating. A line intended 
only for lights cannot properly carry a power tool motor. Wire 
that is heavy enough for a short distance will be too light for 
a greater distance. A line that can support one power tool 
may not be able to support two or three tools.

gROUNDINg INSTRUCTIONS

See Figure 1, page 15.

This product must be grounded. In the event of a  malfunction 
or breakdown, grounding provides a path of least resistance 
for electric current to reduce the risk of electric shock. This 
tool is equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must 
be plugged into a matching outlet that is properly installed 
and grounded in accordance with all local codes and ordi-
nances.
Do not modify the plug provided. If it will not fit the outlet, 
have the proper outlet installed by a qualified electrician.    

 

WARNINg:

Improper  installation  of  the  grounding  plug  is  able  to   
result  in  a  risk  of  electric  shock.  When  repair  or   
replacement of the cord is required, do not connect the 
grounding wire to either flat blade terminal. The wire with 
insulation having an outer surface that is green with or 
without yellow stripes is the grounding wire.

Check with a qualified electrician or service personnel if the 
grounding instructions are not completely understood, or if 
in doubt as to whether the tool is properly grounded.

Repair or replace a damaged or worn cord immediately.

This  product  is  for  use  on  a  nominal  120  volt  circuit  and 
has  a  grounding  plug  similar  to  the  plug  illustrated  in  
figure  1,  page  15.  Only  connect  the  product  to  an  outlet 
having the same configuration as the plug. Do not use an 
adapter with this product. 
Ground Fault Circuit Interrupter (GFCI) protection should be 
provided on the circuit(s) or outlet(s) to be used for the tile 
saw. Outlets are available having built-in GFCI protection 
and may be used for this measure of safety.

ExTENSION CORDS

Use only 3-wire extension cords that have 3-prong ground-
ing plugs and 3-pole receptacles that accept the tool’s plug. 
When using a power tool at a considerable distance from the 
power source, use an extension cord heavy enough to carry 
the current that the tool will draw. An undersized extension 
cord will cause a drop in line voltage, resulting in a loss of 
power  and  causing  the  motor  to  overheat.  Use  the  chart 
provided below to determine the minimum wire size required 
in an extension cord. Only round jacketed cords listed by 
Underwriter’s Laboratories (UL) should be used.

**Ampere rating  (on tool data plate)

 

 

0-2.0 

2.1-3.4 

3.5-5.0  5.1-7.0  7.1-12.0   12.1-16.0

Cord Length   

 Wire Size (A.W.g.)

  25' 

16 

16 

16 

16 

14 

14

  50' 

16 

16 

16 

14 

14 

12

  100' 

16 

16 

14 

12 

10 

**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge

Always use an extension cord that is designed for outside 
use. This is indicated by the letters “W-A” or “W” on the 
cord’s jacket.
Before  using  an  extension  cord,  inspect  it  for  loose  or  
exposed wires and cut or worn insulation.

Use only extension cords that are intended for outdoor use. 
These extension cords are identified by a marking “Accept-
able for use with outdoor appliances; store indoors while not 
in use”. Use only extension cords having an electrical rating 
not less than the rating of the product. Do not use damaged 
extension cords. Examine extension cord before using and 
replace if damaged. Do not abuse extension cords and do 
not yank on any cord to disconnect. Keep cord away from 
heat  and  sharp  edges.  Always  disconnect  the  extension 
cord from the receptacle before disconnecting the product 
from the extension cord.

WARNINg:

Keep  the  extension  cord  clear  of  the  working  area. 
Position the cord so that it will not get caught on lumber, 
tools or other obstructions while you are working with a 
power tool. Failure to do so can result in serious personal 
injury.

WARNINg:

Check  extension  cords  before  each  use.  If  damaged 
replace immediately. Never use tool with a damaged cord 
since touching the damaged area could cause electrical 
shock resulting in serious injury.

Summary of Contents for WS720

Page 1: ...nformidad con nuestras estrictas normas para brindar fiabilidad facilidad de uso y seguridad para el operador Con el debido cuidado le brindar muchos a os de s lido funcionamiento y sin problemas ADVE...

Page 2: ...nted for two years HOW TO GET SERVICE Just return the power tool properly packaged and postage prepaid to an Authorized Service Center You can obtain the location of the Service Center nearest you by...

Page 3: ...skid footwear rubber soled boots are recommended when working outdoors Also wear protective hair covering to contain long hair ALWAYS WEAR SAFETY GLASSES WITH SIDE SHIELDS Everyday eyeglasses have onl...

Page 4: ...Never use washers or arbor nuts that are defective or incorrect The maximum wheel capacity of your saw is 7 in 178 mm Before making a cut be sure all adjust ments are secure Never touch WHEEL or othe...

Page 5: ...better and safer Read The Operator s Manual Safety Alert No Hands Symbol SYMBOL NAME DESIGNATION EXPLANATION Voltage Current Frequency cycles per second Power Time Type of current Type or a characteri...

Page 6: ...n outlet having the same configuration as the plug Do not use an adapter with this product Ground Fault Circuit Interrupter GFCI protection should be provided on the circuit s or outlet s to be used f...

Page 7: ...Diameter 7 in Wheel Arbor 5 8 in Rip Capacity tile size 16 in Diagonal Capacity tile size 12 in Maximum Depth of Cut 1 1 4 in Rating 120 V 60 Hz 4 8 Amps No Load Speed 3 450 r min RPM FEATURES KNOW Y...

Page 8: ...or missing do not operate this tool until the parts are replaced Failure to heed this warn ing could result in serious personal injury warning Do not attempt to modify this tool or create accessories...

Page 9: ...e secure location Adjust to desired angle using angle scale and tighten securely with knob Assembling the stand See Figure 8 9 page 17 The support brackets and stand legs have corresponding letters fo...

Page 10: ...ross cut See Figure 14 page 18 Cross cuts are straight 90 cuts The material is fed into the cut at a 90 angle to the wheel and the wheel is vertical Using a marker or grease pencil mark the area to be...

Page 11: ...get wet before moving the material into the wheel Hold the material firmly against the rip guide and feed the material into the cutting wheel Make the cut far enough into the material without over cu...

Page 12: ...wrench and arbor wrench tighten arbor nut securely Replace bevel table MAINTENANCE WARNING When servicing use only identical Ryobi replacement parts Use of any other parts may create a hazard or cause...

Page 13: ...pay un centre de r parations agr L adresse du centre de r parations agr le plus proche peut tre obtenue en contactant un repr sentant du service apr s vente par courrier l adresse One World Technologi...

Page 14: ...ION RESPIRATOIRE Porter un masque facial ou respiratoire si le travail produit de la poussi re PORTER UNE PROTECTION AUDITIVE Porter une protection auditive durant les p riodes d utilisation prolong e...

Page 15: ...rs 3 fils dot d une fiche prise de terre branch s sur une prise triphas e compatible avec la fiche de l outil NE PAS MODIFIER la fiche fournie Si elle ne peut pas tre ins r e dans la prise secteur fai...

Page 16: ...la s curit d utilisation AVANT d effectuer quelque coupe que ce soit TOUJOURS TEINDRE LA SCIEavant de la d brancher pour viterund marrageaccidentellorsdubranchement pour l utilisation suivante NE JAM...

Page 17: ...aves Avertissement concernant l humidit min Par minute Construction de classe II no Vitesse vide Courant continu Courant alternatif min Minutes W Watts Hz Hertz A Amp res V Volts lectrocution Une mauv...

Page 18: ...ne est le fil de terre Consulter un lectricien qualifi ou le personnel de service si les instructions de mise la terre ne sont pas bien comprises ou en cas de doute au sujet de la mise la terre Cordon...

Page 19: ...rise AVERTISSEMENT Pour r duire le risque d lectrocution garder toutes les connexions s ches et d gag es du sol Ne pas toucher la fiche lorsque les mains sont mouill es Fiche technique Diam tre de la...

Page 20: ...guide longitudinal dans le sens antihoraire pour le desserrer Glisser le guide longitudinal sur le c t de la table D BALLAGE Voir la figure 4 page 16 Ce produit doit tre assembl Sortir soigneusement...

Page 21: ...assurerquelascie carreauxestplac esurunesurface plane et que le support est solide avant d utiliser l outil INSTALLATION DU TUYAU DE TROP PLEIN Voir la figure 10 page 17 Retirer la table de biseau Re...

Page 22: ...aide du bouton EX CUTION DE COUPES Toujours dessiner la ligne tre coup e sur le carreaux utilisant un crayon de borne ou graisse Si le carreaux est brillant et dur la marque le lieu masquant la bande...

Page 23: ...up Couper du mat riel la largeur d sir e utilisant des direc tions pour coupes transversale R gler le guide longitudinal la position d sir e et le serrer UTILISATION solidement Placer le mat riau sur...

Page 24: ...respect de cet avertissement pourrait entra ner des blessures graves Ne jamais utiliser des meules qui ont des ouver tures des rainures ou des dents sur cet outil REMPLACEMENT DE LA MEULE Voir la figu...

Page 25: ...SERVICIO Simplemente env e la herramienta el ctrica debidamente empaquetada y con el flete pagado por anticipado a un centro de servicio autorizado Puede obtener informaci n sobre la ubicaci n del cen...

Page 26: ...ibre 16 A W G por lo menos para un cord n de extensi n de 15 24 metros 50 pies de largo o menos Si tiene dudas utilice un cord n del calibre m s grueso siguiente Cuanto menor es el n mero de calibre m...

Page 27: ...e una clavija de tres puntas debe conectarse en un enchufe el ctrico de tres polos CONSULTE A UN ELECTRICISTA CALIFICADO o t cnico de servicio si no ha comprendido completamente las instrucciones de c...

Page 28: ...ara ver la pieza de trabajo y que ninguna obstrucci n impida una operaci n segura ANTES de efectuar cualquier trabajo con la sierra SIEMPRE APAGUE LA SIERRA antes de desconectarla para evitar un arran...

Page 29: ...en vac o Fabricaci n con doble aislamiento Fabricaci n Clase II Revoluciones carreras velocidad superficial rbitas etc por minuto min Por minuto Potencia W Watts Frecuencia ciclos por segundo Hz Hert...

Page 30: ...el conductor de conexi n a tierra a una terminal portadora de corriente El conductor con aislamiento que tiene una superficie exterior verde con o sin tiras amarillas es el conductor de conexi n a ti...

Page 31: ...por debajo del nivel del tomacorriente o el conector si se utiliza un cable de extensi n que evita que el agua se deslice por el cable y entre en contacto con el tomacorriente Si el enchufe o el toma...

Page 32: ...comodidad Capucha contra salpicaduras El capucha contra salpicaduras proporciona la protecci n del overspray y la niebla CARACTER STICAS DESEMPAQUETADO Vea la figura 4 p gina 16 Este producto requier...

Page 33: ...ve ajustable o llaves des 13 mm y destornillador phillips Introduzca las patas del pedestal marcadas A en los tubos del extremo de la placa de soporte marcada A Los extremos en ngulo de las patas debe...

Page 34: ...so la herramienta siempre retire la llave del interruptor y gu rdela en un lugar seguro En caso de un apag n ponga el interruptor en la posici n de apagado y retire la llave De esta manera se evita un...

Page 35: ...ncendido apagado en la posici n de ENCENDIDO Deje que la muela para cortar adquiera velocidad y es pera para la rueda para mojar antes de mover la mesa de inglete para alimentar la pieza de trabajo a...

Page 36: ...irar cualquier parte de la material FUNCIONAMIENTO Para efectuar cortes en bisel Vea las figuras 18 y 19 p gina 19 Se pueden efectuar cortes a bisel de 22 5 y 45 con la mesa para biselar Utilizar un l...

Page 37: ...ienta La inobservancia de esta advertencia podr a causar posibles lesiones serias Nunca utilice muelas que tengan orificios muescas o dientes con esta herramienta CAMBIO DEL DISCO DE TROCEADO DE AZULE...

Page 38: ...o apagado C Rip guide guide de bord gu a de borde al hilo D Miter guide guide d onglet gu a de ingletes E Max water fill line l eau maximum remplit a ligne agua m xima llena la l nea F Overflow drain...

Page 39: ...apot anti claboussures soporte de la capucha contra salpicaduras J Overflow drain tuyau de trop plein drenaje para derrames K Hex bolt boulon hex perno hexagonal L Bevel table table de biseau mesa par...

Page 40: ...upport A patas de pedestal A C Support bracket B ferrure de support B placa de soporte B D Stand legs B pattes du support B patas de pedestal B Fig 8 Fig 10 Fig 11 A Overflow drain tuyau de trop plein...

Page 41: ...gletes E Miter guide knob bouton du guide d onglet perilla de gu a de ingletes Fig 13 a Fig 14 b Fig 15 Fig 16 cross cut Coupe transversale cortes transversales DIAGONAL cut coupe en diagonale corte d...

Page 42: ...ra biselar Fig 20 d l cut coupe d onglet CORTE A INGLETE BEVEL cut coupe en biseau corte en bisel b Fig 19 A Arbor arbre rbol B Cutting wheel meule de coupe muela para cortar C Hex wrench cl hexagonal...

Page 43: ...20 NOTES NOTAS...

Page 44: ...ces de remplacement peuvent tre achet es en ligne sur le site www ryobitools com ou par t l phone au 1 800 525 2579 Les pi ces de remplacement peuvent tre obtenues un de nos centres de service autoris...

Reviews: