 WARNING

The product should be installed and maintained by 

personnel who are familiar with instruction manual 

and  have  professional  qualification  certificate; 

installation and operation must conform to local 

laws and practical standard; install pipeline properly 

according to instruction manual and anti-freezing 

measures are taken to pipeline.

BEFORE INSTALLATION

Installation precautions of inlet water pipes (Fig. 1, 2)

1.

2.

 

3.  

4.  

5.

 

Examine screw plug for water drainage (Fig. 5)

Dry running function:

Automatic function:

Leak protection function:

CLOCK/TIMER SETTINGS:

6.

 

Installation precautions of outlet water pipes (Fig. 3)

Diameter of outlet water pipes should be at least the 

same as that of water outlet to minimize pressure, 

Choice of installation location (Fig. 4)

When installing pumps, inlet pipelines should be 

as short as possible and elbows should be as few 

as possible. Pumps should be placed in the well-

ventilated environment. Pumps may be installed 

outdoor, but they must be covered to prevent rain 

damage and frost.

MAINTENANCE MANUAL

When there is no water detected by the pump it will 

enter dry run protection. This consists of 3 cycles of 

100 sec "ON" and 5 sec "OFF". If no water is 

detected after 20 seconds on the final cycle the LCD 

screen will display a flashing "ERR" and "       " 

symbol. To reset pump, disconnect from main power 

supply and reconnect. 

The pump will stop when the water flow stops. When 

there is water flow the pump will start automatically, 

this is determined by a drop in pressure in the pump 

head.

When there is low water pressure for a long period 

of time the pump will enter into a pressure check 

mode. The pump will start and stop up to 6 times 

within a 2 minute period. The pump will stop after 1 

hour in this mode and will display a flashing "ERR" 

on the LCD screen.

To enter clock settings press and hold "Menu" 

button for 5 seconds.

CLOCK SETTINGS

Display screen will flash hour first.
Press "D" button to change the hour, then 

press "Menu" to change to minutes use "D" 

to set minutes.
After setting minutes press "Menu" again  to set 

AUTO ON TIME

 and 

AUTO OFF TIME

 repeat the 

same methods as 

setting clock

 .

Do not use a soft rubber hose as it may collapse
during the operation of the electric pump.
Bottom valve must be vertical and 30cm above
bottom to avoid debris being picked up.

All water pipe joints must be sealed with minimal
elbow connections for best performance.
Monitor water level decline when using, and bottom
valve should remain submerged.
Ensure that the water inlet pipe matches the electric
pump inlet pipe diameter.
For additional protection it is recommended to install 

in line filters.

Before use ensure that the screw plug for water

drainage has been installed correctly.

Set inlet water pipes (Fig. 6)

Water pumps are connected with circuits:

Steel wire hose or corrugated pipe (2);

Removable connection nut (3);

Water inlet (4);

Correct operations are as follows: Connect (3) to (2)

(Fig. 6) prior to connecting (3) to (4) (Fig. 6). Ensure

that all connections are sealed correctly.

Set outlet water pipes (Fig. 7)

Installation of outlet water pipes is shown as Fig.7,

the same as installation of water inlet pipes; pay

attention to sealing of pipelines.

Pump operation

1. Fill the suction hose with water. Unscrew the filter

cap (2), then fill the body of the water pump

slowly (2-3 liters) until the water comes out through

the water inlet (1). (Fig. 8)

2. Connect the suction hose to the water inlet (1). 

(Fig. 9)

3. Connect the discharge pipe with the water outlet 

(3)

The pump will start when the switch is turned on.

Clean strainer mesh (Fig. 9)

Clean strainer mesh (Fig. 9)
To maintain optimum water flow performance, users
should clean strainer mesh components regularly
according to water quality. The method to clean is
as follows:
Strainer mesh is rotated as the direction of arrow in
Fig.10 to separate strainer mesh; clean strainer
mesh respectively with clean water; assemble 

strainer mesh and install them properly for use.
If there is any risks of damage due to frost or
freezing, or electric pumps may not be used for
a long time, please open screw plug for water
drainage to discharge water. When pumps are
needed to restart, open pump cover, filled with
water and tighten cover before restart.

Tips:

adjust head height. Once the parameter is set press 

and hold "Menu" to return back to normal operation. 

Summary of Contents for RCPP900-D

Page 1: ...RCPP900 D CONSTANT PRESSURE PUMP MENU DISPLAY...

Page 2: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Page 3: ...TION 1 25mm Water inlet 2 Pre Filter 3 25mm Water outlet 4 Drain plug 5 Pump Head 6 LCD Display screen 7 Carry Handle 8 900W Induction motor with thermal overload 9 Spanner 2 3 6 8 7 1 5 4 9 Component...

Page 4: ...Y MENU DISPLAY MENU DISPLAY MENU DISPLAY MENU DISPLAY MENU DISPLAY MENU DISPLAY LCD DISPLAY Flow Rate Timer Leakage Error Timer ON Setting Pump Head No Flow Error Current Time Setting 3 6 m3 h 39 m 15...

Page 5: ...PUMP INSTALLATION Timer OFF Setting DESCRIPTION MENU 12 00 DISPLAY TIME OFF Fig 4 Fig 6 Fig 5 Fig 3 Fig 2 Fig 1...

Page 6: ...DESCRIPTION Fig 10 Fig 8 Fig 9 Fig 7...

Page 7: ...from any foreign object Risk of uncontrolled situations when used in ambient temperatures below 0 C 32 F or above 40 C 104 F Keep the product dry clean and free from oil and grease Always use a clean...

Page 8: ...NING THE PRE FILTER The pump is fitted with a pre filter which will need cleaning at regular intervals or replacing if necessary It is recommended to clean the non return valve at the 1 Remove the pre...

Page 9: ...o set AUTO ON TIME and AUTO OFF TIME repeat the same methods as setting clock Do not use a soft rubber hose as it may collapse during the operation of the electric pump Bottom valve must be vertical a...

Page 10: ...ower immediately 50Hz SPECIFICATIONS Input Voltage Frequency Weight Pump Dimensions Operation Noise Level Inlet Outlet Size Max Head 240V 10 4kg Rated Power 900W L 470xW 215xHx305 80dB 25 4mm 43m Min...

Page 11: ...rge bottom valve Leakage of suction pipes Examine joints sealing of all suction pipes Deficiency in pressure Inlet water pipes are too long or have too many elbows Pipe diameter is incorrect please re...

Page 12: ...ronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia TechtronicIndustriesN Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand Importe...

Reviews: