background image

8

OPERATION

DANGER.

Do not disassemble any part

of the compressor with air in tank -
bleed the tank. Failure to depressurize
tank could result in explosion and/or
serious personal injury.

WARNING.

Do not allow familiarity with

products to make you careless.
Remember that a careless fraction of a
second is sufficient to inflict severe injury.

WARNING.

Always wear eye protection

with side shields marked to comply with
ANSI Z87.1. Failure to do so could result
in objects being thrown into your eyes
resulting in possible serious injury.

WARNING.

Do not use any attachments

or accessories not recommended by the
manufacturer of this product. The use of
attachments or accessories not
recommended can result in serious
personal injury.

WARNING.

Do not attach any tools to

the open end of the hose until start-up
has been completed.

NOTE.

Do not use in an environment that is dusty

or otherwise contaminated. Using the air
compressor in this type of environment may cause
damage to the unit.

NOTE.

The wiring to a receptacle and the length of

any extension cords being used play an important
role in the operation of this product. Wiring
intended for lights cannot properly carry an air
compressor motor, and wire that is heavy enough
for a short distance may be insufficient for a greater
distance. Before using this product, verify your
receptacle is wired appropriately for air compressor
use and the length and gauge of any extension
cord used is sufficient to carry the current of the air
compressor.

LOCATING THE AIR COMPRESSOR

This compressor should be positioned on a stable,
flat surface (or one with a maximum inclination of
15º). Ensure that it is completely stable.

Do not cover or box in the compressor. Always
position it with good all round ventilation.

MOVING THE AIR COMPRESSOR

Before moving the compressor, switch off and
disconnect it from the mains power supply.

Always use the handle

Do not lift by (or put strain on) air taps, valves
or hoses.

Take care when moving the compressor to
avoid damaging the valves or fittings.

The compressor is heavy, take care when lifting
and moving this compressor to avoid personal
injury. Get assistance if necessary.

This is an “oil less” compressor, this means that
lubrication of moving parts is achieved by using
lubricant impregnated materials, there is therefore
no oil reservoir and the compressor can be
mounted in any orientation without the fear of
spilling oil. The only consideration when mounting
is the position of the water drain cock.

WARNING.

When the compressor is

used for spraying paint or spraying
cleaning agents the fine mist produced
could ignite. When performing this type
of operation the compressor must be a
minimum of 4 Metres away from the
work area. Do not smoke and keep
naked flames and other sources of
ignition well away from the work area.

BASIC COMPRESSOR OPERATION
Important Note:

This manual is provided to allow

the correct assembly and basic safe operation of
the compressor. It must be read in conjunction with
the manual that is supplied with any other
accessory intended for use with this compressor.
For more detailed information on the use of
compressors and accessories, we strongly
recommend that you purchase a good quality
publication, in order to allow you to use this product
to its full potential.

The electric motor drives an air pump which draws
in air from the atmosphere and delivers it into the
air receiver tank through the air receiver tank
supply tube. When the upper calibration value (set
by the manufacturer) has been reached, the
compressor stops.

When air is used, the compressor restarts
automatically when the lower calibration value is
reached (2 bar between upper and lower).

The pressure in the receiver can be checked on the
gauge provided.

Summary of Contents for RC-2050NV

Page 1: ... is intended you will enjoy years of safe reliable service SPECIFICATIONS Voltage 230V 50Hz R Intermittent duty S3 25 ated power 1 5kW 2 0HP Receiver capacity 50l Type Oil free Free air delivery FAD 222l min CFM 7 8 Working pressure 10bar 145psi No load speed 3400min 1 Sound pressure level LpA75 5dB A k 3dB A Sound power level LWA 95 5 dB A k 3dB A Net weight 22 2kg THANK YOU FOR BUYING A RYOBI OI...

Page 2: ... The warnings and safety instructions must be followed to ensure reasonable safety and efficiency in using this product NOTE The operator is responsible for following the warnings and safety instructions in this manual and on the product Ensure that this compressor is disconnected from the mains supply when not in use and the air receiver fully discharged before servicing lubricating or making adj...

Page 3: ...afe Never weld or drill holes in the air tanks Only use recommended parts To avoid the risk of bursting only hoses with a rated pressure of 8 bar or more should be used Never attempt to repair faulty hoses Avoid kinking or trapping the air hose Always replace faulty hoses never attempt a repair if a leak is detected Make sure the hose is free of obstructions or snags Entangled or snarled hoses can...

Page 4: ... with ANSI Z87 1 c Additional safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When requ...

Page 5: ...ompressor ELECTRICAL ELECTRICAL CONNECTION This product is powered by a precision built electric motor It should be connected to a power supply that is 230 V AC only normal household current 50 Hz Do not operate this product on direct current DC A substantial voltage drop will cause a loss of power and the motor will overheat If the product does not operate when plugged into an outlet double check...

Page 6: ...le 2 On Off switch 3 Wheels 4 Condensation drain tap 5 Rubber foot 6 Air receiver tank 7 Shroud 8 Air outlet pressure gauge 9 Air outlet quick release connector regulated 10 Pressure regulator DESCRIPTION 1 2 3 7 6 8 4 5 9 10 ...

Page 7: ...Rubber foot Rubber foot fixings bolt washer nut x 2 Operator s Manual WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not connect to power supply until assembly is complete Failure to comply could result in accidental starting and possible seriou...

Page 8: ...R COMPRESSOR Before moving the compressor switch off and disconnect it from the mains power supply Always use the handle Do not lift by or put strain on air taps valves or hoses Take care when moving the compressor to avoid damaging the valves or fittings The compressor is heavy take care when lifting and moving this compressor to avoid personal injury Get assistance if necessary This is an oil le...

Page 9: ... zero 0 psi Connect a hose to the compressor using the hose to compressor quick release connector Fig 3 Make sure to push the air fitting fully into the coupler until the sleeve springs forward to lock in place To disconnect an air hose or an air tool Confirm that the outlet pressure is at zero 0 psi When disconnecting a hose from the quick release connector always firmly hold the fitting end of t...

Page 10: ...ltage is 230V The ON OFF switch is in the OFF non depressed position The pressure regulator should be set at its lowest setting i e turned fully anticlockwise If the machine has not been used for 24 hours or so open the drain valve tap to drain any condensate which may have accumulated When clear close the valve Important If the receiver is under pressure keep your hands well away from the air bei...

Page 11: ...any maintenance always disconnect the compressor from the mains supply drain the air receiver and if necessary allow the machine to cool down before starting work GENERAL MAINTENANCE The compressor must be drained completely by opening the drain tap Drain the air receiver tank after approx 2 hours of use WARNING If the water that condenses is not drained it may corrode the receiver reducing its ca...

Page 12: ...ucts in the conveyor Ventilate the work area Activate the on off switch Ventilate the work area Wait a few minutes The compressor will restart independently Remove any power cable extensions Remove the plug and contact the Service Centre SERVICE Now that you have purchased your tool should a need ever exist of repair or service simply contact your nearest Ryobi Authorised Service Centre or other q...

Page 13: ... Hazardous Voltage Disconnect from power source before servicing Do not use in damp conditions Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Unexpected Starting The compressor may start without warning Recycle Symbol Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority ...

Page 14: ...NOTES 14 ...

Page 15: ...15 NOTES ...

Page 16: ......