background image

5

If you experience any of the symptoms of this 

condition, immediately discontinue use and 

see your doctor.

 WARNING

Injuries may be caused, or aggravated, by 

prolonged use of the product. When using 

any tool for prolonged periods, ensure you 

take regular breaks.

KNOW YOUR PRODUCT

See page 8.

1.  Fan cover

2.  Upper vacuum tube

3.  Lower vacuum tube

4.  Guide wheels

5.  High speed nozzle

6.  Lower blow tube

7.  Upper blow tube

8.  Vacuum bag

9.  Bag adaptor

10.  Blower/vacuum mode selection lever

11.  Front handle

12.  Speed selector

13.  Rear handle

14.  On/Off trigger

SYMBOLS ON THE PRODUCT

Read and understand 

all instructions before 

operating the product, follow 

all warnings and safety 

instructions.

Beware of thrown or flying 

objects. Keep all bystanders, 

especially children and pets, 

at least 15 m away from the 

operating area.

Rotating fans. Keep hands 

and feet out of openings while 

the product is running.

Wear ear protection.

Wear eye protection.

Do not expose to rain or 

damp condition.

Switch off: remove plug from 

mains before cleaning or 

maintenance

Remove plug from the 

mains immediately before 

maintenance or if cable is 

damaged or cut.
Conforms to all regulatory 

standards in the country in 

the EU where the product is 

purchased.

EurAsian Conformity Mark

Ukrainian mark of conformity.

Class II tool, double insulation

Waste electrical products 

should not be disposed of 

with household waste. Please 

recycle where facilities exist. 

Check with your local authority 

or retailer for recycling advice.

108

The guaranteed sound power 

level is shown on this label by 

108 dB.

Blower mode

Vacuum mode

SYMBOLS IN THIS MANUAL

Connect to power outlet.

Disconnect from power outlet.

Note

Warning

Summary of Contents for RBV3000CESV-01

Page 1: ...RBC36X26E RBC36X26E ORIGINAL INSTRUCTIONS Electric Blower Vacuum RBV3000CESV 01...

Page 2: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Page 3: ...re tired ill or under the influence of alcohol drugs or medicine ELECTRICAL SAFETY Power plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded...

Page 4: ...inspect the housing for damage Ensure that guards and handles are in place and properly secured Return to an authorised service centre to replace damaged or unreadable labels Never operate the product...

Page 5: ...orking on the product to inspect the product for damage after striking a foreign object if the product starts to vibrate abnormally inspect immediately WARNING Your blower vacuum may be supplied with...

Page 6: ...roduct with a soft dry cloth Check all nuts bolts and screws at frequent intervals for proper tightness to ensure the product is in safe working condition Any part that is damaged should be properly r...

Page 7: ...rs especially children and pets at least 15 m away from the operating area Rotating fans Keep hands and feet out of openings while the product is running Wear ear protection Wear eye protection Do not...

Page 8: ...if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially h...

Page 9: ...7 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1...

Page 10: ...8 11 12 6 5 4 7 8 9 10 1 2 3 13 14...

Page 11: ...1 2 1 7 2...

Page 12: ...3 8 4...

Page 13: ...9 1 3 4 5 2 1 2 1 2 5 9 6...

Page 14: ...10...

Page 15: ......

Page 16: ......

Page 17: ...11 p 12 p 12 p 13 p 15 p 17 p 18 p 19...

Page 18: ...12 2 2 1 1...

Page 19: ...13 1 1 2 2 3 4...

Page 20: ...14 6 5 7 8...

Page 21: ...15 1 1 2 1 4 3 2 2 3 4...

Page 22: ...16 1 2 5 1 2 6 7 8...

Page 23: ...17 1 3 2 1 2 3...

Page 24: ...18 1 2...

Page 25: ...19 4 3 2 1 2 1 6 2 1 3 4 5 2 4 1 3 20160627v3...

Page 26: ...of 50636 2 100 2014 Rear handle 6 8 m s2 Front handle 4 0 m s2 Uncertainty of measurement 1 5 m s2 A weighted emission sound pressure level at the operator s position in accordance with Annex CC of 50...

Page 27: ...removed any damage caused by non observance of the instruction manual any product not displaying the CE approval mark on the rating plate any product that has been attempted to be repaired by a non a...

Page 28: ...rs Kent CT10 2UG Phone 01843 869400 Email repairs cjsinclairltd co uk Web www cjsinclairltd co uk Powertech Ind Ltd Unit 2C Ellison Road Norwood Ind Killamarsh Sheffield South Yorkshire S21 2JG Phone...

Page 29: ...U EN 60335 1 2012 A11 2014 EN 50636 2 100 2014 EN ISO 3744 2010 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 62233 2008 EN 50581 2012 Measured...

Page 30: ......

Page 31: ......

Page 32: ...Techtronic Industries GmbH Max Eyth Stra e 10 71364 Winnenden Germany...