Ryobi RAIW-G Operator'S Manual Download Page 8

5

 

Use the product only for its intended purpose.

MAINTENANCE

 

Keep the product safe by regular maintenance.

 

Always keep your air tool clean and lubricated. Daily 

lubrication is essential to avoid internal corrosion and 

possible failure.

 

Lubricate the product daily with a few drops of air tool 

oil dripped into the air inlet.

 

Maintenance shall be performed weekly.

 

Drain the air tank daily. Water in the air line will 

damage the product.

 

If the product cannot be used anymore, make sure to 

dispose of it so as not to impose hazards on people 

and the environment.

 

Air tool white oil is recommended for lubrication.

 

Only lubricants recommended by the manufacturer 

should be used.

 

Clean the air inlet filter weekly.

TROUBLESHOOTING

 WARNING

If any of the following symptoms appears during 

operation, stop using the product immediately, or 

serious  personal  injury  could  result.  Only  qualified 

persons or an authorised service centre can perform 

repairs or replacement of the product.

Disconnect the product from the air supply before 

attempting repair or adjustment. When replacing O-rings 

or cylinder, lubricate with air tool oil before assembly.

PROBLEM: Product runs at normal speed but fails 

under load.

POSSIBLE CAUSES

 

Motor parts are worn.

 

Cam clutch is worn or sticking due to lack of lubricant.

REMEDIES

 

Lubricate clutch housing.

 

Check for excess clutch oil. Clutch cases need only 

be half full. Overfilling can cause drag on high speed 

clutch parts, i.e. a typical oiled/lubricated tool requires 

14.20 ml (1/2 ounce) of oil.

Grease lubrication
NOTE:

 Heat usually indicates insufficient grease in 

chamber. Severe operating conditions may require 

more frequent lubrication.

PROBLEM:  Product

  runs  slowly.  Air  flows  slightly 

from exhaust.

POSSIBLE CAUSES

 

Motor parts are jammed with dirt particles.

 

Power regulator is in closed position.

 

Air flow is blocked by dirt.

REMEDIES

 

Check air inlet filter for blockage.

 

Pour air tool lubricating oil into air inlet as per instructions.

 

Operate the product in short bursts quickly reversing 

rotation back and forth where applicable.

 

Repeat above as needed.

PROBLEM: Product will not run. Air flows freely from 

exhaust.

POSSIBLE CAUSE

One or more motor vanes are stuck due to material 

build up.

REMEDIES

 

Pour air tool lubricating oil into air inlet.

 

Operate the product in short bursts of forward and/or 

reverse rotation where applicable.

 

Tap motor housing gently with a plastic mallet.

 

Disconnect the air supply. Free the motor by rotating 

drive shank manually where applicable.

 

If the product remains jammed, return to the service 

centre. 

PROBLEM: Product

 will not shut off.

POSSIBLE CAUSE

‘O’ rings throttle valve is dislodged from seat inlet 

valve.

REMEDY

Replace the ‘O’ ring.

NOTE:

  Repairs  should  be  carried  out  by  a  qualified 

person.

Summary of Contents for RAIW-G

Page 1: ...AIR IMPACT WRENCH TWIN HAMMER OPERATOR S MANUAL ORIGINAL INSTRUCTIONS RAIW G ...

Page 2: ...Important It is essential that you read the instructions in this manual before operating this machine Subject to technical modifications ...

Page 3: ...er 8 Adjustment knob 9 Counterclockwise 10 Clockwise torque 1 11 Clockwise torque 2 12 Clockwise torque 3 DESCRIPTION 4 6 2 1 5 3 Fig 1 Fig 2 Fig 4 Fig 3 Fig 5 Quick connector Quick connector Lubricator Filter Cut off valve Regulator 0 8 5 bar Quick coupler Tool Air compressor Quick coupler Air hose 7 8 9 10 11 12 ...

Page 4: ... hands away from rotating drives OPERATING HAZARDS The use of the tool can expose the operator s hands to hazards including crushing impacts cuts and abrasions and heat Wear suitable gloves to protect hands Operators and maintenance personnel shall be physically able to handle the bulk weight and power of the tool Hold the tool correctly be ready to counteract normal or sudden movements and have b...

Page 5: ...rdance with employer s instructions and as required by occupational health and safety regulations Operate and maintain the assembly power tool for threaded fasteners as recommended in the instructions handbook to prevent an unnecessary increase in noise levels If the assembly power tool for threaded fasteners has a silencer always ensure it is in place and in good working order when the assembly p...

Page 6: ... Lubricate with air tool oil daily SPECIFICATIONS Square drive 12 7 mm 1 2 Capacity bolt size 16 mm 5 8 No load speed 7 800 min Max torque 569 N m Avg air consumption 184 L 6 5 cfm Maximum working pressure 6 3 bar 90 psi Air inlet size 6 35 mm 1 4 Air hose ID 9 52 mm 3 8 Weight 2 1 kg A weighted sound pressure level 95 1dB A k 3dB Sound power level 106 1dB A k 3dB Vibration value 5 778 m s2 Uncert...

Page 7: ...ributed throughout the product The product should be stored in a clean and dry environment It is most important that the product be properly lubricated by keeping the air line lubricator filled and correctly adjusted Without proper lubrication the product will not work properly and parts will wear prematurely Use correct lubricant in the air line lubricator The lubricator should be of low air flow...

Page 8: ...ack of lubricant REMEDIES Lubricate clutch housing Check for excess clutch oil Clutch cases need only be half full Overfilling can cause drag on high speed clutch parts i e a typical oiled lubricated tool requires 14 20 ml 1 2 ounce of oil Grease lubrication NOTE Heat usually indicates insufficient grease in chamber Severe operating conditions may require more frequent lubrication PROBLEM Product ...

Page 9: ...ng 15 x 2 65 4 Anvil bushing 15 Bolt 4 x 46 26 Spring 37 Retaining ring 5 Washer 16 Cylinder 27 Steel ball 38 Plug cover 6 O ring 7 5 x 1 8 17 Cylinder cap 28 Screw M5 x 88 5 39 Plug 7 Output shaft 18 Bearing 6001 29 Bolt 2 5 x 33 40 Valve stem 8 Hammer cage 19 Circlip 30 O ring 3 x 1 41 Spring 9 Hammer pin 20 Housing 31 Trigger 42 Air inlet 10 Hammer dog 21 Gasket 32 Bolt 11 Bearing R8 22 O ring ...

Page 10: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand ...