![Ryobi Homelite RY48ZTR75/100 Manual Download Page 33](http://html1.mh-extra.com/html/ryobi/homelite-ry48ztr75-100/homelite-ry48ztr75-100_manual_1505112033.webp)
Testing Master and Slave
Blade
Motors
Nominal resistance 0.1 Ohm
1. Disconnect Motor from controller.
2. Set DMM to
Resistance
mode.
3. Measure between any 2 pins.
4. Measure between other pins.
5. Measurements should be nearly identical.
33
***IMPORTANT***
IGNORE
the
“N”, “L” and “G” labels on the
connector. These are
NOT
for
“Neutral”, “Line” and “Ground”
NEVER connect to AC Power!