![Ryobi Homelite RY48ZTR75/100 Manual Download Page 25](http://html1.mh-extra.com/html/ryobi/homelite-ry48ztr75-100/homelite-ry48ztr75-100_manual_1505112025.webp)
Testing the Neutral Switches
25
1. Set meter to measure continuity and connect probes
2. With switch NOT pressed, measure
no
continuity
3. With switch pressed, measure continuity
4. Make sure wires and connector are in good shape and wires don’t pull loose
Note: the switches are pressed when the steering arms are in the out position