background image

7

EXTENSION CORDS

When using a power tool at a considerable distance from 
a power source, be sure to use an extension cord that has 
the  capacity  to  handle  the  current  the  tool  will  draw.  An  
undersized cord will cause a drop in line voltage, resulting in 
overheating and loss of power. Use the chart to determine 
the minimum wire size required in an extension cord. Only 
round jacketed cords listed by Underwriter’s Laboratories 
(UL) should be used.
When working outdoors with a tool, use an extension cord 
that is designed for outside use. This type of cord is desig-
nated with “WA” on the cord’s jacket.
Before  using  any  extension  cord,  inspect  it  for  loose  or  
exposed wires and cut or worn insulation.

**Ampere rating  (on tool data plate)

 

 

0-2.0 

2.1-3.4 

3.5-5.0  5.1-7.0  7.1-12.0   12.1-16.0

Cord Length   

 Wire Size (A.W.G.)

  25' 

16 

16 

16 

16 

14 

14

  50' 

16 

16 

16 

14 

14 

12

  100' 

16 

16 

14 

12 

10 

**Used on 12 gauge - 20 amp circuit.

NOTE: AWG = American Wire Gauge

WARNING:

Keep  the  extension  cord  clear  of  the  working  area. 
Position the cord so that it will not get caught on lumber, 
tools or other obstructions while you are working with a 
power tool. Failure to do so can result in serious personal 
injury.

WARNING:

Check  extension  cords  before  each  use.  If  damaged 
replace immediately. Never use tool with a damaged cord 
since touching the damaged area could cause electrical 
shock resulting in serious injury.

ELECTRICAL

DOUBLE INSULATION

Double insulation is a concept in safety in electric power 
tools,  which  eliminates  the  need  for  the  usual  three-
wire  grounded  power  cord.  All  exposed  metal  parts  are  
isolated  from  the  internal  metal  motor  components  with 
protecting  insulation.  Double  insulated  tools  do  not  need 
to be grounded.

WARNING:

The  double  insulated  system  is  intended  to  protect 
the user from shock resulting from a break in the tool’s 
internal insulation. Observe all normal safety precautions 
to avoid electrical shock.

NOTE: Servicing of a tool with double insulation requires 
extreme care and knowledge of the system and should be 
performed only by a qualified service technician. For service, 
we suggest you return the tool to your nearest authorized 
service center for repair. Always use original factory replace-
ment parts when servicing.

ELECTRICAL CONNECTION

This tool has a precision-built electric motor. It should be 
connected to a 

power supply that is 120 volts, 60 Hz, AC 

only (normal household current). Do not operate this tool 
on direct current (DC). A substantial voltage drop will cause 
a loss of power and the motor will overheat. If the tool does 
not operate when plugged into an outlet, double-check the 
power supply.

Summary of Contents for DS11008

Page 1: ...lity ease of operation and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the...

Page 2: ...ars HOW TO GET SERVICE Just return the power tool properly packaged and postage prepaid to an Authorized Service Center You can obtain the location of the Service Center nearest you by contacting a se...

Page 3: ...our finger on the switch or plugging in tools that have the switch on invites accidents Remove adjusting keys or wrenches before turning the tool on A wrench or a key that is left attached to a rotati...

Page 4: ...and if damaged have repaired at your nearest Authorized Service Center Constantly stay aware of cord location Following this rule will reduce the risk of electric shock or fire Check damaged parts Be...

Page 5: ...or s Manual To reduce the risk of injury user must read and understand operator s manual before using this product Eye Protection Always wear safety goggles or safety glasses with side shields and as...

Page 6: ...e product to the nearest AUTHORIZED SERVICE CENTER for repair When servic ing use only identical replacement parts WARNING To avoid serious personal injury do not attempt to use this product until you...

Page 7: ...before each use If damaged replace immediately Never use tool with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury ELECTRICAL DOUBLE INSULATION...

Page 8: ...action with excellent sanding results As the name implies this tool has been designed primarily for detailed and intricate sanding i e refinishing furniture chairs etc enabling you to sand in places...

Page 9: ...ing on wood surfaces Removing rust from and sanding steel surfaces Polishing and buffing Scraping paint or glue from window panes INSTALLING SANDPAPER See Figure 2 Thefeltpadonthesanderacceptspressure...

Page 10: ...nder the sander WARNING Unsecured work could be thrown towards the operator causing injury Hold sander in front and away from you keeping it clear of the workpiece Start sander and let the motor build...

Page 11: ...pack 4615100 100 Grit Sanding Angles 10 pack 4615150 150 Grit Sanding Angles 10 pack 4615220 220 Grit Sanding Angles 10 pack 4615500 Sanding Angle Assortment 10 pack 4615505 Preparation Pad For Wood...

Page 12: ...n ordering repair parts always give the following information MODEL NUMBER SERIAL NUMBER DS11008 OPERATOR S MANUAL DETAIL SANDER DOUBLE INSULATED DS11008 Ryobi is a registered trademark of Ryobi Limit...

Reviews: