background image

Ensure that you read, understand, and apply the 
safety instructions.
Reminder: DO NOT vacuum hazardous substances.
The use of an incorrect dust bag will invalidate the 
warranty.

Ensure that the power cord is disconnected from the 
outlet.

DRY VACUUMING

Ensure that the HEPA cartridge filter is completely mounted.
Ensure that the filter is inserted all the way. (Fig. 13)

Verify that the dust bag is installed to the inside of the 
tank (Fig. 8).

Replace the top section on the tank, and secure it in 
place using the clamps (Fig. 10).

Insert the larger end of the hose into the front inlet on the 
tank and lock it in place. Push the required attachment 
on to the free end of the hose or extension (Fig.12).

Plug the power cord in to the power outlet.

Turn the motor on by flipping the switch to the ‘I’  (ON)
position (Fig. 14).

Once you have finished vacuuming, flip the switch to the 
‘O’ (OFF) position and unplug the power cord from the 
power outlet. (Fig. 15)

DO NOT USE THE HEPA CARTRIDGE FILTER FOR WET 
OR SHARP MATERIALS.

DO NOT USE DUST BAG FOR LIQUID VACUUMING.

 WARNING

 WARNING

OPERATION

WET VACUUMING

For dry vacuuming, install the supplied HEPA cartridge 
filter and dust bag (Fig. 7, Fig. 8).

For wet vacuum cleaning, install the supplied foam filter 
only (Fig. 9).

Replace the top section on the tank (Fig. 10).

Align the top section with the clamps and snap into place 
by applying pressure until clamps click (Fig. 10).

Insert the large end of the hose into the front inlet of the 
tank and turn to lock (Fig. 11).

Fit the required accessory on to the suction tube (Fig. 12).

3

Ensure that the power cord is disconnected from the 
power outlet.
Ensure that the tank is clean and free of dust and dirt.

Remove the HEPA cartridge filter and dust bag, and install a 
foam filter over the filter basket and place the top section 
back on the tank (Fig. 9).
DO NOT use the HEPA cartridge filter for wet or sharp materials.

Fit the desired nozzle to the vacuum hose (Fig. 12).

Ensure that the switch is in the ‘O’ (OFF) position before 
plugging the power cord into the power outlet.

Turn the motor on by flipping the switch to the “I” (ON)
position (Fig. 14).

After use, flip the switch to the “O” position (Fig. 15) and 
unplug the power cord, then empty and dry the tank 
(Fig. 16).

BLOWER OPERATION

The foam filter must be removed after wet vacuuming, 
and a HEPA cartridge filter must be installed before dry 
vacuuming again.

 WARNING

Always wear safety goggles before using blower.

 WARNING

Wear a dust mask if blowing creates dust that might
be inhaled.

 WARNING

Keep bystanders clear from blowing debris.

 WARNING

Ensure that you read, understand, and apply the 
safety instructions.
Reminder: DO NOT vacuum hazardous substances.

 WARNING

When vacuuming large quantities of liquids, do not immerse 
the nozzle completely in the liquid; leave a gap at the tip of 
the nozzle opening to allow air inflow.
The machine is fitted with a float valve that stops the 
suction action when the container reaches its maximum 
capacity. You will notice an increase in motor speed.
When this happens, turn off the machine, disconnect from 
power supply, and drain the liquid into a suitable receptacle 
or drain. To continue vacuuming, refit the container with the 
drain cap. After wet vacuuming, turn the machine off and 
remove plug from power supply.
Empty the container, clean and dry the inside and outside 
before storage.

This Wet/Dry Vac has blowing capabilities.
To use the blower feature follow the instructions listed.

IMPORTANT!

Improper filter assembly may cause motor failure.
Please refer to instruction below.

 WARNING

DRY VACUUMING

+

WET VACUUMING

Paper Bag

Foam Filter 

Cartridge Filter

Summary of Contents for 0057838

Page 1: ...RVC 1420C G...

Page 2: ...Important It is essential that you read the instructions in this manual before operating this machine Subject to technical modifications...

Page 3: ...5 Foam filter wet areas 6 Dust bag 7 Castor x4 8 Screws 9 Handle 10 Blower connection 11 Filter basket 12 Safety float valve 13 HEPA cartridge filter dry areas 14 Filter cap x1 15 ON OFF switch 16 Co...

Page 4: ...DESCRIPTION Please refer to pages 2 4 for instructions 2 1...

Page 5: ...DESCRIPTION Please refer to pages 2 4 for instructions...

Page 6: ...DESCRIPTION Please refer to pages 2 4 for instructions...

Page 7: ...Fig 23 DESCRIPTION Please refer to pages 2 4 for instructions Fig 20 Fig 21 Fig 22 Fig 24 Fig 25...

Page 8: ...DESCRIPTION Please refer to pages 2 4 for instructions Fig 26 Fig 27 Fig 28 Fig 29 Fig 30...

Page 9: ...ric household appliances make sure that the cable can t cause children to stumble and don t give children access to the appliance Never use the appliance when you are under the influence of medication...

Page 10: ...cords should not be repaired they should be replaced with an equivalent type ASSEMBLY Ensure that the power cord is disconnected from the power outlet Undo the clamps Fig 2 Lift the top section off t...

Page 11: ...nd dust bag and install a foam filter over the filter basket and place the top section back on the tank Fig 9 DO NOT use the HEPAcartridge filter for wet or sharp materials Fit the desired nozzle to t...

Page 12: ...retailer for recycling advice Please read the instructions carefully before starting the machine Safety Alert Volts Hertz Alternating Current Watts MAINTENANCE Conformity Install the dry filter over...

Page 13: ...ank is full of liquid Dust is escaping from the motor cover The dust bag is missing or damaged Put in a dust bag or replace it Low suction power and high motor speed vibrations Dust bag is full Replac...

Page 14: ...Techtronic Industries Australia Pty Ltd 31Gilby Road Mt Waverley VIC 3149 Australia Techtronic Industries New Zealand Ltd 2 Landing Drive Auckland Airport Mangere New Zealand 2022...

Reviews: