Operation Guide
Part 1
– How to Load and Light your Melter
1. Ensure your regulator is off by rotating regulator nob fully counter-clockwise (rotate left).
2. Slowly pressurize the regulator by rotating the valve located on the propane cylinder counter-clockwise all
the way (rotate left).
3. Inspect and ensure there are no leaks between any of the connections before proceeding.
4. Load crack sealant into kettle, while ensuring sealant is resting on the bottom of the kettle.
5. Pressurize the propane hose by rotating the regulator knob fully clockwise (rotate right).
6. Press and hold the electric igniter button immediately followed by the burner starter button. Continue
holding both buttons until the burner ignites.
7. Once the burner ignites, release the electric igniter button, however continue to hold the starter button for
an additional 15-20 seconds. This will eventually deactivate the flame-out sensor which is responsible for
ensuring the burner stays lit.
8. Once lit, you can control the temperature by adjusting the regulator.
⚠
Operating the burner on high in most conditions is not recommended, this can harm sensitive electronic
components and dangerously overheat fuel carrying lines.
⚠
Never exceed the manufacturer's recommended material maximum temperature.