background image

 

Operation Guide

 

 
Part 2 

– Agitating and Monitoring Temperature 

1.  Never leave melter unattended when the burner is lit. If flame goes out, promptly turn off the flow of gas; 

double check that the melter is free and clear of any gas odors before attempting to re-ignite the burner. 

2.  While your melter is ignited you should continuously be monitoring the material temperature. Check with 

crack sealant manufacture for safe melting temperatures and ensure you continually adjust your regulator 
to maintain the recommended temperature range. If the material becomes too hot, you may need to turn off 
your burner periodically. 

3. 

As material begins to melt, it’s important to consistently agitate. Agitation moves the solid crack sealant 
along the bottom and prevents ‘hot spots’ from forming which can alter the effectiveness of the sealant 
after applied. Agitation also prevents chunks of over-heated material from forming which will eventually  
plug or block your flow valve which can slow down the applications process.  

 

 
Part 3 

– Dispensing Crack Filler 

Once you have effectively liquefied the crack sealant, you may begin applying it. For best results, the surface 
should be clean and free of dirt, debris and vegetation. Ensure shoe is lowered and resting on the pavement. 
Push melter into position, aligning the crack you wish to fill with the center of the shoe. Slowly squeeze the 
valve control arm until crack filler begins to come out of the valve and onto the crack. Slowly push the melter 
forward, keeping the crack aligned with the center of the shoe. Increase speed of the material flow by 
squeezing harder on the valve control arm. If material flow slows, check to ensure that you have enough 
melted material in the kettle and agitate to keep the flow tube clear. 
 

 
Part 4 

– Turning Off and Draining 

Once you have finished using the melter, make sure it is fully drained and no crack filler remains inside the 
kettle or the flow valve. Leaving the flow valve empty after use will prevent the valve from being blocked the 
next time you use the melter. 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

Summary of Contents for RA-MLT-0013

Page 1: ...s Manual Model RY10MA Pro V4 MPN RA MLT 0013 10 Gallon Direct Fire Melter Applicator Burner Model with Flame Out Sensor U S Patent No 9 739 021 For Technical Support Please Message us on WhatsApp 519...

Page 2: ...ed it must be properly requalified to continue using Ensure that your propane cylinder is within its expiry date for your local jurisdiction The manufacturing date is stamped on the collar of the tank...

Page 3: ...o purchase the correct material to ensure safe and effective operation Within this document are complete instructions for how to assemble use and care for your equipment Please make sure you read and...

Page 4: ...Assembly Instructions 1 Tank Shelf 2 Tank Spacer RK FAS 0066 13 mm Wrench RK FAS 0067 13 mm Wrench...

Page 5: ...3 Rear Wheels 4 Casters RK FAS 0080 Assemble wheels on axle the side with the bearing retainer ring should be facing out RK FAS 0065 19 mm or Wrench Insert pin...

Page 6: ...ned so it is perpendicular to the ground before the bolts are tightened The lock washers provided for the valve are shipped in pairs Use 1 pair for each bolt with the wedged surfaces on the washers ma...

Page 7: ...andle Bars Tighten the handle bar nuts so that they are snug nuts will be fully tightened in the set up section Bend the handle bars over the mounting studs one side at a time RK FAS 0083 19 mm or Wre...

Page 8: ...7 Thermometer RK FAS 0071 13 mm Wrench Thread the thermometer into the kettle...

Page 9: ...Agitation Attach the agitation handle with the hardware preassembled on the handle bars Remove the 2 bolts on the agitation connector handle and insert the handle into the slot and over the stud insid...

Page 10: ...Install the agitation sweep bar as shown put it over the left stud first and then the right Attach the agitation sweep bar by reassembling the bolts to the agitation connector handle...

Page 11: ...9 Lid Handle RK FAS 0070 13 mm Wrench...

Page 12: ...10 Burner Install 1 Insert the burner tray into the guide tracks at the back of the kettle 2 Insert burner retainer pin through the slot in the shelf and into the grommet on the burner tray...

Page 13: ...11 Shoe Control Arm Insert the shoe control handle into the lower guide Insert the lower end of the shoe control rod into the shoe tab and insert the retaining pin...

Page 14: ...r guide Insert the lower end of the control rod into the valve connector rod and insert the retaining pin Turn the valve connector rod clockwise until it is tight and then turn it approximately 1 rota...

Page 15: ...ne tank Place your propane tank on the shelf and secure with the ratchet strap Only tighten the ratchet strap so that it is snug do not apply excess force on the brackets Connect the regulator to the...

Page 16: ...Set Up Handle Bars Adjust the handle bars to a comfortable height for the operator and tighten the flanged nuts on the studs x2 each side...

Page 17: ...to be adjusted to the appropriate length so that they function properly Remove the spring retainer pin to put tension on the valve control rod Put a screwdriver through the hole in the turnbuckle to t...

Page 18: ...in the position shown below Valve control arm should be approximately 1 2 past the guide Shoe control arm should be approximately 1 past the guide Once the control rod lengths are set use a screwdriv...

Page 19: ...Set Up Adjust Spring Tension The spring tension on the valve control arm can be adjusted by setting the pin position shown below which will increase or decrease the spring tension...

Page 20: ...Set Up Installing Igniter Battery Unthread the igniter cap and insert the AA battery with the positive terminal facing up...

Page 21: ...no leaks or physical damage 4 You are outdoors in a well ventilated area that is free and clear of any flammable matter 5 You have completed the assembly of the equipment correctly 6 You have Direct...

Page 22: ...otate right 6 Press and hold the electric igniter button immediately followed by the burner starter button Continue holding both buttons until the burner ignites 7 Once the burner ignites release the...

Page 23: ...will eventually plug or block your flow valve which can slow down the applications process Part 3 Dispensing Crack Filler Once you have effectively liquefied the crack sealant you may begin applying i...

Page 24: ...are recommended Description Before Each Use Every 25 Hours Every 75 Hours Check Propane Tank fuel level refill as needed X Inspect regulator and hose for physical damage or leaks X Inspect front cast...

Page 25: ...you hold your starter button until the burner ignites continue to hold for an additional 15 20 seconds 3 Check and refill your fuel tank 4 Ensure your fuel valve is fully open you can do this by turn...

Reviews: