6
MINI CRIMPER SERIES OPERATION MANUAL
Follow procedures herein to fill the RY16-HP or
RY16-AP oil reservoir with hydraulic oil the equivalent of
RYCO Hydraulic Oil 46. It is recommended to pump the oil
into the reservoirs through a 20μ filter, to avoid transferring
impurities. If any oil spills, clean up immediately with a
RYCO Spill Kit.
Oil Fill
Battery and Oil
These items are governed by International shipping
requirements. Generally they will not have batteries
installed and will be delivered dry. Check the oil
tank and fill as required prior to use using procedure
herein.
RYCO SPILL KIT
RYCO HYDRAULIC OIL
GENERAL
SAFETY RULES
The Master Dies are greased at the point of
manufacture after final testing. This should not be
relied on to protect the crimper during initial use.
Prior to commissioning, the machine should be
greased according to operating Instructions.
Greasing of the master dies is critical to ensuring a
long and trouble-free life for the crimper.
Greasing frequency should be increased when
operating in aggressive or high volume environments.
Friction
Pressure Heat
Impurity
Time
Volume
Recommended Greasing Time
Greasing
Running-In
Recommended run-in period for a new machine is 2 crimps.
It is recommended the greasing process is carried out at least
twice a day, more if the machine is in constant use.
The purpose of frequent greasing is to ensure that there is
always enough grease between the sliding surfaces. Due to
the surface pressure the grease sinks in to the metal pores
ensuring good sliding properties for the machine’s lifetime.
During the run-in period grease the machine after every
100 crimps.
Summary of Contents for MINI CRIMPER Series