4
EasyStove
Installation, Usage and Maintenance Instructions
1
Heat Exchanger
2
System Pump
3
Air Vent
5
Stove Circuit Pump
6
Electrical Box
7
Non Return Valve
8
Cover
A
Flow to System
C
Return from System
D
Return to Stove
E
Flow from Stove
03. TECHNICAL INFORMATION
Stove Circuit
Fluid Type
Water
Max. Temperature
90°C
Max Operating Pressure
6 bar
Secondary Circuit
Fluid Type
Water
Max Temperature
90°C
Connections
Material
Brass
Size
3/4”
Casing and Cover
Material
Galvanised Steel
Colour
RAL9010
Power Supply
Voltage
230V
Frequency
50Hz
Power
100 W
Protection
IP56
Environmental
Installation Location
Indoors
Ambient Temperature
5 - 55°C
Ambient Humidity
25 - 85% RH
Weight incl. Cover
11.0 kg
PRINCIPAL COMPONENTS