Prepare Remote Control
1. Determine a location to install the wall remote control within the interior of the RV.
2. Drill a 3/4" hole and clean the edges.
3. If necessary, run two electrical wires that extend the wall control connections (blue wires) to the appliance connections
(blue wires) using the appropriate wire size. 16AWG max. 65ft (20m).
Install Appliance
1. Remove the appliance from its packaging.
2. Remove protective caps for COLD (blue) and HOT (red) water along with any caps for the gas inlet.
3. Open the front access door.
4. Position the appliance into the frame opening.
5. Ensure that the electrical power switch on the front of the appliance is set to the OFF position.
6. Ensure that the gas supply is turned OFF.
7. Connect the gas service line to the gas inlet on the back of the appliance.
DO NOT
overtighten.
17