USE AND MAINTENANCE MANUAL R68090150
ORIGINALE
RUTHMANN ITALIA S.r.l. Via Santa Maria del Piano di sotto,91/B
–
47854 Montescudo-Monte Colombo (RN) - ITALIA
pag. 34
12.
Free
-
without function
13.
P
ush button “Minimum
jacking”
-
Jacking variant with stabilizing jacks within the vehicle
profile on both sides.
-
Activates push button for re-entering the extendible front
outriggers.
14.
Push
button
“Jack
activation
“
press for activating the controls of extendible front stabilizers
and outriggers cylinders
Permanent light: outriggers’ control is enabled
15.
Free
without function
16.
Push
button
“Full
jacking”
-
Jacking variant with front stabilizing jacks extended
horizontally on the left and right.
-
Activates push button for extending the extendible front
outriggers.
!
WARNING
ATTENTION
Please refer to chapter 8 for a full description of the functionality of each button.
The operators and maintenance staff must read this manual before using the machine and
before making any maintenance operation.
The
WHITE LED is ON
when the control of upper part of platform is
activated and there are the following conditions for lifting the booms:
- platform is stabilized and chassis is levelled,
- the lifting functions are active,
- there is not any malfunctioning of platform that could block all boom
functions (
…
as breakdown of a safety sensor). In case of a malfunctioning,
the led is off and an alarm message appears on the display of remote
control. If the malfunctioning causes the block of only a part of lifting
movements, the white led continues to be on. If led is off and there isn’t
any alarm message on display, the operator has to check the previous
conditions and if the emergency compartment located on the right side of
platform is open.
The
ORANGE LED is ON
when the control of lower part of platform is
activated and there are the following conditions for controlling the
outriggers: - boom in rest position,
- the outriggers functions are active,
- there is not any malfunctioning of platform that could block all outrigger
functions (
…
as breakdown of a microswitch on stabilizer). In case of a
malfunctioning, the led is off and an alarm message appears on the
display.
If led is off and there isn’t any alarm message on display, the
operator has to check the previous conditions.