background image

 The Diagnostics Menu also contains the update firmware procedure for updating the UNO-S2's firmware. To access the Diagnostics Menu, press and hold

the Setup button on the right side of the keypad until "DIAGNOSTICS" appears on the display. The menus are outlined in the diagram on the next page. When

finished, press and release the Setup button again (except for the Update Firmware where the power must be cycled). Note: Do not change Controller ID

settings in this menu. Controller ID is set in the Controller Setup Menu of the controller only. 14 INSTALLER GUIDE UNO-S2 Keypad Diagnostics Menu

Press and Hold Setup Button DIAGNOSTICS CONTROLLR ID PORT ID KEYPAD ID VERSION UPDATE FIRMW Displays Controller ID number Displays

Port ID number Displays Keypad ID number Displays current firmware version Hold PLAY After update cycle Power Start Update Cycle Power BUTTON

TEST DISP CHAR DISP BLOCK DISP ROW BG COLOR Press button to be tested Press button to display character Press button to display blocks Press

button to display rows Select Amber, Green, or turn color Off 15 INSTALLER GUIDE UNO-S2 Keypad Firmware Update Note: When a firmware update is

released, it is available online at the Document Center on www.russound.

com, in Technical Documents under Multi-zone products. The firmware update procedure may be modified, so always check for the latest version.

Requirements: 1. PC computer running Windows 95, 98, ME, NT, 2000, XP operating system 2. Available DB-9 serial RS-232 data port (baud rate= 38400,

data bits = 8, no parity, 1 stop bit, no flow control) 3.

UNO serial Programming Cable (Russound P/N 2500-121036 4. Flash Magic - Philips IC update application (Flash Magic can be downloaded for free at:

http://www.esacademy.com/software/flashmagic/flashmagic.exe) Note: the same A/C power circuit should be used for the keypad/sys16 tem and the PC.

Otherwise a ground loop may affect proper data transfer. Update Procedure: Two OS update methods are available: A and B. Method A enters the OS

Update mode through the keypad's Diagnostics Menu and requires no access to the rear panel of the keypad. Method B enter the OS Update mode by

repositioning a jumper on the rear panel of the keypad. Method A: Enter the Diagnostics Menu by holding the "Setup" button for approximately 4 seconds

until "Diagnostics" appears on the display. The Setup button is located behind the trim cover plate on the right hand side of the keypad above the OS Update

port. Once in the Diagnostics Menu, press the left or right arrow key until "UPDATE FIRMW" is displayed. Press the "Play" key to enter the menu.

INSTALLER GUIDE UNO-S2 Keypad Firmware Update Then press and hold the "Play" key for approximately 2 seconds until "Start Update" is displayed.

Now the keypad is ready for update.

Method B: Move the OS Update jumper on the rear panel of the keypad to the Update position (on both pins). Press the Reset button located next to the OS

update jumper. At this point, the display will be backlit and blank but the buttons will be dark. Method A and B: Start the Flash Magic application. If error

messages appear, they are typically generated due to communication problems. Connect the UNO Programming Cable between the PC COM port and the

keypad Update port. Verify all connections. Flash Magic Required Settings: Section 1: COM Port: = COM port connected to on PC Baud Rate: = 38400

Device: = XA-G49 Oscillator Freq. {MHz}: = 12.288 Section 2: "Erase blocks 0-4" should be highlighted Note: Check "Erase all Flash + Security.

" Also un-check "Set Security Bit 1-3" found in Section 4. Section 3: Click "Browse" button to select the new .hex file to be used. Section 5: Click the "Start"

button to begin firmware update. The status is shown at the bottom of the window.

Completion: Disconnect the Programming Cable from the keypad and the PC. (Method B: Re-position the OS Update jumper to Run.) Cycle main power off

and on. 17 INSTALLER GUIDE UNO-S2 Keypad Location Plastic Double-Gang Electrical Box (36 ci) UNO-S2 Back Plate Screw Screw Screwless Cover
Plate 18 INSTALLER GUIDE UNO-S2 Keypad Location Installation Location The best infrared remote performance is achieved with the keypad installed

away from any direct sunlight, plasma TV, and low voltage lighting controls.

You're reading an excerpt. Click here to read official RUSSOUND
UNO-S2 user guide

http://somemanuals.com/dref/77396

Reviews: