Russound CA 4.4i Instruction Manual Download Page 9

9

PUNCHDOWN TERMINALS

Figure 11

– Punchdown 

Terminal on CAi keypad

The CAi Keypads come with 110 punchdown terminals. These
terminals are quick, easy to install and provide a strong con-
nection. Punchdown terminals require the use of a punch-
down tool. One has been provided with this kit.

Press wires into punchdown terminal with punchdown tool
as shown in Figure 12.

Figure 12

– Punching Down Wires

INSTALLING THE KEYPADS

• The best infrared remote performance is achieved with

the keypad away from any direct sunlight. Also consider
convenience when choosing a location.

• Choose a place that is easily seen from the position where

a person is most likely to be located. 

• Check whether or not you can route the wire to the loca-

tion you have chosen.

• Purchase retro-fit plastic junction boxes (min. 18 cubic

inches) or p-rings and cut in the boxes using a key-hole
saw or sheetrock knife/hand saw.

• If you are installing the optional DSC keypad you will

need to use a double-gang electrical box. If you are
installing both the optional DSC and DAN keypad  you
will need to install a triple-gang electrical box.

• If you feel uncomfortable cutting into your walls and

running wire through the walls, seek help from a profes-
sional installer or an electrician.

• Route the wire to the junction box from the CAi location.

• If using 22 AWG wire, connect each wire to the correct

position 1 thru 8 using the included punchdown tool.
Refer to List 5.

• If using CAT-5 wire, connect each wire to its correspon-

ding color labeled on the punchdown terminal.

• Mount the keypad in the junction box and attach the

Decora© plate.

• The CA-KP2 keypad has source labels for your conven-

ience. Insert the label in the keypad keeping the input
number in sequence with the source selected.

• Repeat the above steps until all keypads are installed.

I

NSTALLING

K

EYPADS

IR

GND

+12V

CH SE

L

SEL3

SEL1

BA

L

VO

L

CAT-5 or 8-conductor

22 AWG wire

Connector on  

CA-KP2 or CA-LCD2

BRO

WN 

GREEN 

ORANGE

BLUE

Punchdown
Tool

CAi-Series manual  10/17/02  11:01 AM  Page 9

Summary of Contents for CA 4.4i

Page 1: ...ler Amplifier 1 2 3 4 5 6 ZONE REMOTE SENSOR ON OFF VOLUME SOURCE R B CHILDRENS ROCK JAZZ REMOTE SENSOR VOLUME SOURCE STORE POWER CA4 4i 4 Zone 4 Source Central Controller Amplifier POWER 1 2 3 4 ZONE...

Page 2: ...ces The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance 11 Grounding or Polarization The precautions that should...

Page 3: ...nnecting the Infrared Components 7 Connecting the IR Link 7 Keypad Connections at Controller 8 Wiring at the Controller 8 Clean Installations 8 Installing Keypads 9 Punchdown Terminals 9 Installing th...

Page 4: ...bility and Quality are the primary objectives Russound products are guar anteed to provide years of enjoyment The CAi conforms to UL and CSA safety specifications POSSIBLE SYSTEM CONFIGURATIONS PRODUC...

Page 5: ...onnectors If you have problems or you are not absolutely comfortable with what you are doing consult a professional carpenter electrician or system installer BASIC PLANNING AND LAYOUT CONSIDERATIONS W...

Page 6: ...______ Zone 3 ________________ Zone 4 ________________ REAR PANEL CONNECTIONS 1 R L 2 1 R L 2 3 4 CA6 4i NEWMARKET NH U S A 110VAC 220 240VAC 50 60Hz 400W VOLTAGE 110V 220 240V FUSE F4A F2A KEYPAD POR...

Page 7: ...gh a 1 8 male mini plug The tip is and the sleeve is 12VDC When more than one CAi is used connect the MUTE OUT of the first CAi to the MUTE IN of the second CAi Figure 7 DIM 1 Doorbell Interface Modul...

Page 8: ...s from the Wall Plate KEYPAD CONNECTIONS AT CONTROLLER KEYPAD PORTS 1 2 3 4 1 2 3 4 5 6 7 8 CAT 5 Cable RJ 45 using T568A Wiring Standard Each keypad connection on the back panel of the CAi Series Mas...

Page 9: ...and saw If you are installing the optional DSC keypad you will need to use a double gang electrical box If you are installing both the optional DSC and DAN keypad you will need to install a triple gan...

Page 10: ...grammer is compatible with DAN and DSC IR Keypads which have a 5 pin programming port located at the top left of the keypad Refer to IKP 1 Instruction Manual for complete instructions 1 Loads IR code...

Page 11: ...using the optional SRM 2 1 speaker relay module wire the terminals of the CA LCD2 to the SRM 2 1 terminals Figure 16 SRM 2 1 connection to CA LCD2 Refer to the SRM 2 1 Instruction Manual for complete...

Page 12: ...on the keypad will also illuminate to verify the zone is now on Note The CAi front panel zone management lights also informs you which zones are On or Off 2 Volume Up Down Once the unit is on the kno...

Page 13: ...ne of the 23 preset source names for each of the four sources Select the source name that you want to change by selecting source Press and hold the store button for approximately 3 seconds and the dis...

Page 14: ...device may have been activated Please take the following steps to troubleshoot the system 1 Turn off the power switch on the front of the CAi Series controller 2 Disconnect all keypad connections fro...

Page 15: ...n transit TROUBLESHOOTING WARRANTY COMBINING ADDITIONAL IR RECEIVERS When combining a CAi Series multi source controller and a secondary IR system together it needs to be done after the CAi System The...

Page 16: ...A V D I S T R I B U T I O N C O N T R O L S Y S T E M S 5 Forbes Rd Newmarket NH 03857 603 659 5170 Fax 603 659 5388 e mail tech russound com Come visit us at 28 0106...

Reviews: