For Customer Services & Spare Parts please call
0845 208 8750
Opening times: Monday - Friday 8am – 6pm & Saturday 9am – 1pm
or visit us at
www.productcareuk.com
20
Error codes
Status of
Corresponding
Indicators
Description
Reason
Solution
Temp. 20 Flashes
Temp. 40 Off
Temp. 60 Off
Temp. 90 Off
Door lock fault.
•
Door is not closed
properly or door lock is
faulty.
•
Close the door and
press start.
Temp. 20 Off
Temp. 40 Flashes
Temp. 60 Off
Temp. 90 Off
Water intake fault.
(Water intake exceeds
7 minutes)
•
Tap is not open or water
pressure is low.
•
Inlet valve filter is
blocked.
•
Inlet hose is twisted.
•
Open the tap or wait
for the water
pressure to increase.
•
Check the inlet valve
filter.
•
Straighten the inlet
hose.
Temp. 20 Flashes
Temp. 40 Flashes
Temp. 60 Off
Temp. 90 Off
Drainage fault.
(Drainage time
exceeds 3 minutes)
•
Outlet hose is blocked or
twisted.
•
Drain pump is blocked or
faulty.
•
Check the outlet
hose for twists or
blockages.
•
Remove and clean
the filter.
Note:
Fault indication lights are located on the control panel above the temperature button.
All repairs to your machine should be carried out by a qualified engineer or contact Product
Care on
0845 208 8750.