background image

ASSEMBLING THE POLISHING MOP

Press the polishing mop to attach it to the back-up pad.

BEFORE STARTING THE POLISHER

Ensure that:

•the power supply conforms with the characteristics of the tool

(see tab “Minimum Gauge for Cord Sets”);

•the power supply cable and plug are in perfect condition;

•the ON/OFF switch works properly though with the power

supply disconnected;

•all the parts of the tool have been assembled in the proper

manner and that there are no signs of damage;

•the ventilation slots are not obstructed.

FAILURE TO START

Should your tool fail to start, check to make sure the prongs on

the cord plug are making good contact in the outlet. Also, check

for blown fuses or open circuit breakers in the line.

REPLACING THE POLISHING MOP

Pull the used polishing mop off and apply the new one, pressing

it onto the disc pad.

ACCESSORIES

Polishing  mops  Ø130-Ø150mm  (LHR12E)  for  Ø125mm

back-up pads and polishing mops Ø80-Ø100 mm (LHR75E)

for Ø75mm back-up pads .

MAINTENANCE

Maintenance and cleaning of the inner parts, like brushes, ball

bearings, gears etc. or others, must be carried out only by an

authorized customer service workshop.    

CLEANING

CHANGING BACK-UP PAD 

Loosen the screw (4) using the supplied wrench (Pic. 1-2). 

Remove the used pad, place the new one turning it slightly until

is fixed to the right position (Pic. 3-4). Tighten the screw using

the wrench.    

WARNING: Blow dirt and dust out of all air vents with

clean, dry air at least once a week.

To minimize the risk of eye injury, always wear ANSI Z87.1

approved eye protection when performing this.

WARNING: Never use solvents or other harsh chemicals

for  cleaning  the  non-metallic  parts  of  the  tool.  These

chemicals may weaken the plastic materials used in these

parts. Use a cloth dampened only with water and mild

soap.  Never  let  any  liquid  get  inside  the  tool;  never

immerse any part of the tool into a liquid.

1

2

4

3

10

4

10

4

CAUTION:  Accessories  must  be  rated  for  at  least  the

speed  recommended  on  the  tool  warning  label.

Accessories running over rated speed can fly apart and

cause injury. Accessory ratings must always be above

tool speed as shown on tool nameplate. 

WARNING: To reduce the risk of injury, turn unit off and

disconnect it from power source before installing and

removing accessories, before adjusting or when ma-

king repairs. Be sure the switch is in the “OFF” posi-

tion. An accidental start-up can cause injury.

CAUTION: Accessories must be rated for at least the

speed  recommended  on  the  tool  warning  label.

Accessories running over rated speed can fly apart and

cause injury. Accessory ratings must always be above

tool speed as shown on tool nameplate. 

Press the polishing mop to attach it to the back-up pad.

LUBRICATION

This tool has been lubricated with a sufficient amount of high

grade lubricant for the life of the unit under normal operating

conditions. No further lubrication is necessary.

WARRANTY

Complying with current applicable regulations and subject to

more favorable conditions that could apply in different coun-

tries, RUPES professional tools are supplied with a 12 months

warranty against manufacturing defects from date of purchase.

Only Rupes original parts and accessories must be employed

with RUPES tools. Rupes is not responsible for any damages or

accidents caused by not abiding to this rule and the warranty

shall terminate if non-original parts are employed. Damages

caused by natural wear and tear, overloading, faulty mainte-

nance and tool usage differing from the one specified in the user

guide, are not covered by this warranty. A tool which has been

proven faulty must be delivered to an authorized Rupes service

center along with its fully filled out warranty certification and

document of purchase. Warranty shall be void if tool should be

delivered disassembled or tampered. This warranty does not in

any way imply tool’s replacement. RUPES SpA reserves the

right to make specifications or design changes to its products

without further notice. RUPES does not accept any responsibi-

lity for any possible printing mistake. This document superse-

des all previously printed one.

FREE LABEL REPLACEMENT: If your labels become illegible or

are  missing,  cal  0039  02  94  694  1  RUPES spa  for  a  free

replacement.

Summary of Contents for BIGFOOT DUETTO LHR12E

Page 1: ...AD and UNDERSTAND the instruction manual before using AVERTISSEMENT Pour votre propre sécurité veillez à bien LIRE et COMPRENDRE le présent manuel d instructions avant d utiliser la machine ADVERTENCIA Por su propia seguridad lea el manual de instrucciones antes de utilizar el aparato SAVE THESE INSTRUCTIONS CONSERVER CES DIRECTIVES CONSERVE ESTA INSTRCCIONES ...

Page 2: ...he switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations f Dress properly D...

Page 3: ...e uncontrolled power tool to be forced in the direction opposite of the accessory s rotation at the point of the binding For example if a polishing mop is snagged or pinched by the workpiece the edge of the mop that is entering into the pinch point can dig into the surface of the material causing the mop to climb out or kick out The mop may either jump toward or away from the operator depending on...

Page 4: ...disperse dust which may cause serious and permanent respiratory or other injury Always use NIOSH OSHA approved respiratory protection appropriate for the dust exposure Direct particles away from face and body CAUTION Use extra care when working into a corner because a sudden sharp movement of the polisher may be experienced when the polishing mop or other accessory contacts a secondary surface or ...

Page 5: ...re your power supply agrees with the voltage marked onthe nameplate 120 Volts AC 60Hz means alternating currentonly Voltage decrease of more than 10 will cause loss of power and overheating PARTS OF THE TOOL 1 Identification plate 2 ON OFF switch 3 Electronic speed control 4 Back up pad fixing screw 5 Handle 6 Polishing mop not supplied 7 Handle fixing screws 8 Velcro faced back up pad 9 Motor ven...

Page 6: ...ed speed can fly apart and cause injury Accessory ratings must always be above tool speed as shown on tool nameplate WARNING To reduce the risk of injury turn unit off and disconnect it from power source before installing and removing accessories before adjusting or when ma king repairs Be sure the switch is in the OFF posi tion An accidental start up can cause injury CAUTION Accessories must be r...

Page 7: ...ous servez d un outil électroportatif N utilisez jamais un outil électroportatif lorsque vous êtes fatigué ou sous l influence de la drogue de l alcool ou d un traitement médical Un simple instant d inattention lors de l utilisation d un outil électroportatif peut être à l origine de blessures corporelles graves b Utilisez un équipement de protection individuelle Portez toujours une protection ocu...

Page 8: ...re doit être capable de filtrer les particules générées par l opération réalisée Une exposition prolongée à des bruits d intensité élevée peut causer une perte de sensibilité auditive 9 Tenez les passants ou spectateurs à distance de sécurité de la zone de travail Toute personne pénétrant dans la zone de travail doit porter un équipement de protection individuelle Des fragments de matière ou d acc...

Page 9: ...iser en fonction de la longueur de câble électrique voulue et de l intensité nominale mentionnée sur la plaque signalétique En cas de doute utilisez le calibre immédiatement supérieur Plus le chiffre désignant le calibre est petit plus le câble est gros Calibre minimal de conducteurs pour rallonge s électrique s Les risques encourus par suite d une telle exposition varient en fonction de la fréque...

Page 10: ...de l interrupteur INTERRUPTEUR MARCHE ARRÊT AVERTISSEMENT Pour réduire le risque de blessure s assurer que la polisseuse ne soit pas posée sur la pièce à usiner quand on appuie sur l interrupteur Pour allumer la polisseuse pousser le levier de l interrupteur 2 vers le corps de l outil Pour éteindre la polisseuse pousser vers l arrière et relâcher le levier de l interrupteur VARIATEUR DE VITESSE ÉL...

Page 11: ...ne éliminez la poussière et la saleté de toutes les ouïes de ventilation de l outil par soufflage à l air propre et sec Pour minimiser les risques de lésions oculaires portez toujours une protection oculaire homologuée ANSI Z87 1 lorsque vous effectuez cette opération AVERTISSEMENT Ne vous servez jamais de solvants ou autres produits chimiques agressifs pour nettoyer les éléments non métalliques d...

Page 12: ...ante casco protección auditiva etc usados de forma adecuada también contribuyen a evitar lesiones c Evite que las herramientas se puedan poner en marcha de forma accidental Asegúrese de que el interruptor está en la posición de apagado antes de conectar las herramientas a la toma de corriente o a la batería de recogerlas y de transportarlas Transportar herramientas eléctricas con el dedo cerca del...

Page 13: ... desgarrar el cable o puede alcanzarle en la mano o en el brazo con el accesorio rotatorio 12 No suelte la herramienta eléctrica hasta que el accesorio se haya detenido completamente El accesorio rotatorio puede atascarse en la superficie del material y hacer que pierda al control de la herramienta 13 No ponga la herramienta eléctrica en funcionamiento mientras esté cargando con ella El contacto a...

Page 14: ...te el contacto persistente con el polvo de pulido Use ropa de protección y lávese las áreas expuestas con agua y jabón En caso de que le entre polvo en la boca o en los ojos o que este permanezca sobre su piel su cuerpo puede absorber productos químicos dañinos ADVERTENCIA UTILICE SIEMPRE gafas de seguridad Las gafas comunes NO son gafas de seguridad Utilice también máscaras de protección o antipo...

Page 15: ...r 11 Botón de bloqueo del interruptor INTERRUPTOR DE ENCENDIDO APAGADO ADVERTENCIA Para reducir el riesgo de lesiones com pruebe que la pulidora no reposa en la pieza de trabajo cuando la encienda Para encender la pulidora pulse la palanca del interruptor 2 hacia el cuerpo de la herramienta Para apagar la pulidora pre sione hacia atrás y libere la palanca del interruptor Para apagar la pulidora su...

Page 16: ... Elimine el polvo de todos los orificios de ventilación con aire seco y limpio una vez a la semana por lo menos Para minimizar el riesgo de lesiones oculares utilice siempre protección aprobada ANSI Z87 1 al realizar esta operación ADVERTENCIA No utilice disolventes u otros productos químicos agresivos para limpiar las partes no metálicas de la herramienta Estos productos pueden debilitar los mate...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...RUPES S p A Street Marconi 3A Loc Vermezzo 20071 VERMEZZO CON ZELO Mi Italy Tel 39 02 946941 Fax 39 02 94941040 e mail info_rupes rupes it web http www rupes com Cod 9 2478 USA 10 2013 ...