R11-10TDW

ERV UNIT SCHE MATIC DIAGRAM

COM PO NENT  CODE

A131

Fixed Re lay Board

B26

Mo tor,  Ex haust  Air

B27

Mo tor, Fresh Air

B28

Mo tor,  Des ic cant  Wheel

B30

Motor, Damper (Op tional)

C23

Capacitor, Wheel Motor

C25

Ca paci tor,  Mo tor  Ex haust  Air

C26

Ca paci tor,  Mo tor  Fresh  Air

DL43

De lay, Cy cle Timer (Op tional)

F29

Fuse

J33

Jack, Cy cle Control (Op tional)

J34

Jack, Cy cle Con trol Harness (Op tional)

J40

Jack, Cy cle  (Op tional)

J48

Jack, Con trol Box (Fresh Air)

J50

Jack, Con trol Box (Wheel)

J51

Jack, Con trol Box (Ex haust Air)

J56

Jack, Con trol Box (Damper)

J148

Jack, Fresh Air Mo tor Harness

J150

Jack, Wheel Mo tor Harness

J151

Jack, Exhaust Air Mo tor Harness

J152

Jack, Trans former (High Volt age)

J153

Jack, Field Harness

J160

Jack, Damper Mo tor Harness

K94

Re lay, On/Off (Op tional)

K163

Re lay, Ex haust Air Motor

K164

Re lay, Fresh Air Motor

P33

Plug, Cy cle Control (Op tional)

P34

Plug, Cy cle Con trol Harness (Op tional)

P40

Plug, Wheel Cycle (Op tional)

P48

Plug, Fresh Air Mo tor Harness

P50

Plug, Wheel Mo tor Harness

P51

Plug, Ex haust Air Mo tor Harness

P56

Plug, Damper Mo tor Harness

P148

Plug, Fresh Air Motor

P150

Plug, Wheel Mo tor

P151

Plug, Exhaust Air Motor

P152

Plug, Trans former (High Volt age)

P153

Plug, Field Harness

P160

Plug, Damper Motor

S23

Ther mo stat  -  Low  Am bi ent  (Op tional)

S26

Switch, Low Am bi ent (Op tional)

S51

Switch, Door

S125

Switch, Am bi ent Override (Op tional)

T27

Trans former,  Control

T28

Trans former,  Step- down  (Op tional)

T47

Trans former,  Step- down  (Op tional)

TB57

Terminal Block - High Voltage

WIRE COLOR

BK

Black

BL

Blue

GR

Green

GY

Gray

OR

Orange

Notes:
1. Remove jumper to install field optional low ambient switch.
2. Step-down transformer assembly for 460/575 volt units.
3. Selective voltage terminal for proper unit voltage
4. Optional low ambient switch.
5. Optional motorized intake damper.
6. Unit may be wired for HI, MED, or LO speeds. Diagram shows the HI speed setup, to rewire for MED or LO speed, disconnect 

BK-101 from relays and connect BL-101 for MED, or RD-101 for LO. Also connect WH-101 to BK-101.

7. Optional stop, start and jog control.
8. Matching adapter harness (provided) to connect with rooftop unit. For energy management systems c24v to green 

and common 24v to black.

PAGE 6

Summary of Contents for RRS ROOFTOP YCD/TCD

Page 1: ...rve energy by mixing warmer air with cooler air in the following manner Recovery Mode The Recovery Mode is accomplished by two blowers providing continuous exhaust of stale indoor air and replacement...

Page 2: ...s CEC Refer closely to unit wiring diagram in unit and or in these instructions for proper wiring connections Refer to the unit nameplate for minimum circuit ampacity and maximum overcurrent protectio...

Page 3: ...lators the frost threshold is typically below 15o F Frost threshold is dependent on indoor temperature and humidity The table shows how the frost threshold temperatures vary depending on indoor condit...

Page 4: ...g of ERV segment does not affect its performance Only excessive buildup of foreign material need be removed If the segment appears excessively dirty it should be cleaned to ensure maximum operating ef...

Page 5: ...1 27 1 26 1 25 1 23 1 2 1 18 1 17 1 15 1 13 1 12 1 09 1 06 0 99 0 91 1 05 1 02 0 95 0 8 0 65 0 0 2 0 4 0 6 0 8 1 1 2 1 4 700 750 800 850 900 950 1000 1050 1100 1150 1200 SCFM Equation of Line SCFM PD...

Page 6: ...g Exhaust Air Motor Harness P56 Plug Damper Motor Harness P148 Plug Fresh Air Motor P150 Plug Wheel Motor P151 Plug Exhaust Air Motor P152 Plug Transformer High Voltage P153 Plug Field Harness P160 Pl...

Page 7: ...tional low ambient switch 5 Optional motorized intake damper 6 Unit may be wired for HI MED or LO speeds Diagram shows the HI speed setup to rewire for MED or LO speed disconnect BK 101 from relays an...

Page 8: ...PAGE 8...

Reviews: