EN
9. TROUBLESHOOTING
Try the suggestions below to see if you can solve the problem before calling the service
center or the manufacturer.
PROBLEM
CAUSE
SOLUTIONS
The engine is
not working
Lack of power supply
Check the connection plate with
a tester
The safety thermostat is
on
Wait about a minute, then
restart
The engine
works, but the
burner does
not ignite after
a few
seconds, the
heating
system stops
The gas valve of the
cylinder is closed
Open the gas tap
The bottle is empty
Use a new bottle
The nozzle is blocked
Remove the nozzle and clean it
Solenoid gas valve it is
not open
Check that the solenoid valve is
working
Don't spark
Check the position of the
electrode
The burner
ignites, but
after a few
seconds, the
heating
system stops
There is no connection to
the grounding system
Check and connect properly
Malfunction between
sensor and safety device
Check and connect properly
Defective safety device
Replace the safety device
The heater
stops during
operation
Excessive gas supply
Check the pressure reducer
and, if necessary, replace it
Insufficient air flow
Check that the engine is
working properly
Insufficient gas supply
due to the formation of ice
on the cylinder
Check and use a larger cylinder
or two bottles connected
together.
Summary of Contents for VULCANO 881
Page 1: ...MANUAL DE UTILIZARE RURIS VULCANO 881 882 883 884 ...
Page 38: ...EN USER MANUAL RURIS VULCANO 881 882 883 884 ...
Page 45: ...EN 5 DESCRIPTION OF THE CONTROL PANEL 1 Quartz 2 Switch 3 Gas valve 6 CIRCUIT DIAGRAM ...
Page 63: ...HU HASZNÁLATI UTASÍTÁS RURIS VULCANO 881 882 883 884 GÁZZAL MŰKÖDŐ HŐLÉGFÚVÓ ...