![Runco Video Xtreme VX-44d Installation & Operation Manual Download Page 29](http://html1.mh-extra.com/html/runco/video-xtreme-vx-44d/video-xtreme-vx-44d_installation-and-operation-manual_1500089029.webp)
Controls and Functions
Runco VX-44d/-55d Installation/Operation Manual
13
PRE
L
IMINAR
Y
Inputs
4.
USB
A standard, USB Series “B” connection to a personal computer. (For future use.)
5.
HDMI 1 / HDMI 2 (Digital)
HDCP-compliant digital video inputs for connecting an HDMI or DVI source.
6.
HD1 / HD2 (5 x Analog BNCs)
Two inputs (five BNCs per input) for connecting standard-definition (SD = 480i/576i),
enhanced-definition (ED = 480p/576p) or high-definition (HD = 720p/1080i/1080p)
component video sources, or RGBHV sources such as personal computers.
7.
Component / SCART (5 x RCA connectors)
SD/HD input for connecting SDTV, EDTV or HDTV component video sources, or
RGBHV sources. Also provides RGB input for SCART RGBS sources.
8.
Video
Standard, composite video input for connecting a VCR, camcorder or other
composite video source. Also provides composite sync input for SCART RGBS
sources.
9.
S-Video 1 / S-Video 2
Two, standard S-Video inputs for connecting a DVD player, satellite receiver or Super
VHS (S-VHS) VCR.
10.
IR
Wired input from a Niles- or Xantech-compatible, infrared (IR) repeater system. It is a
3.5-mm, mini phono jack, wired as follows:
Ring = No connection
Tip = IR Input
Sleeve = Ground
11.
RS-232 / RS-485
A female, 9-pin D-sub connector for interfacing with a PC or automation/control
system. (Currently, only RS-232 interface is supported.)
12.
MAIN AC FUSE
This is the main AC input fuse (5mm x 20mm, 500 mA, 250V slow-blow).
13.
MAIN POWER SWITCH
Disconnects or applies power to the DHD Controller.
14.
POWER INPUT (100 to 240 VAC)
Connect the DHD Controller to power here.
Summary of Contents for Video Xtreme VX-44d
Page 2: ......
Page 10: ...x Runco VX 44d 55d Installation Operation Manual P R E L I M I N A R Y Notes...
Page 68: ...Installation 52 Runco VX 44d 55d Installation Operation Manual P R E L I M I N A R Y Notes...
Page 118: ...Specifications 102 Runco VX 44d 55d Installation Operation Manual P R E L I M I N A R Y Notes...
Page 119: ......
Page 120: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 0826 02 Rev B April 2009...