Q-750i Series Installation/Operation Manual
83
PRE
L
IMINAR
Y
RS-232 Error Codes
If an
errcode ?
command returns one of the following values, you have encountered a
likely system error requiring the attention of a qualified service technician. Try resetting the
projector by powering it off, allowing it to cool and powering it on again. Refer to Table 6-3
and contact your dealer if the problem persists.
The specific code number identifies the source of the error detected, and is particularly
useful in cases where the projector is far away. For example, the code “7” means that
Fan 1 has failed.
Table 6-3. RS-232 Error Codes
Error Code
LED Indication
Description
0
Inlet NTC thermal sensor is over temperature.
1
Outlet NTC thermal sensor is over temperature.
2
Red LED thermal sensor is over temperature.
3
Green LED thermal sensor is over temperature.
4
Blue LED thermal sensor is over temperature.
6
Fan failure upon system power-up.
7
Fan 1 failed.
8
Fan 2 failed.
9
Fan 3 failed.
10
Fan 4 failed.
11
Fan 5 failed.
12
Fan 6 failed.
15
DDP3021 communication failure upon system
power-up.
19
PCF8575 external GPIO communication failure.
21
Gennum SP1 communication failure upon system
power-up.
22
System hardware I2C communication failure.
23
System software I2C communication failure.
24
EEPROM checksum error.
25
EDID checksum error.
Summary of Contents for Q-750i Series
Page 2: ......
Page 10: ...x Q 750i Series Installation Operation Manual P R E L I M I N A R Y Notes...
Page 14: ...Table of Contents xiv Q 750i Series Installation Operation Manual P R E L I M I N A R Y Notes...
Page 58: ...Installation 42 Q 750i Series Installation Operation Manual P R E L I M I N A R Y Notes...
Page 86: ...Operation 70 Q 750i Series Installation Operation Manual P R E L I M I N A R Y Notes...
Page 107: ......
Page 108: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1018 00 Rev A October 2009...