![Runco CINEWIDETM VX-3000D Installation & Operation Manual Download Page 83](http://html1.mh-extra.com/html/runco/cinewidetm-vx-3000d/cinewidetm-vx-3000d_installation-and-operation-manual_1500000083.webp)
Operation
VX-3000d Series Installation/Operation Manual
67
PRE
L
IMINAR
Y
PLUGE patterns vary but generally consist of some combination of black, white and gray
areas against a black background. The example above includes two vertical bars and four
shaded boxes.
Select Brightness from the Picture menu and press
ENTER
. Adjust the brightness so that:
• The darkest black bars disappear into the background.
• The dark gray areas are barely visible.
• The lighter gray areas are clearly visible.
• The white areas are a comfortable level of true white.
• The image contains only black, gray and white (no color).
Contrast:
On your external test pattern source, select a stepped, gray-bar pattern like the
one shown in Figure 4-3.
Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast
Select Contrast and press
ENTER
. Adjust the contrast to a point just below which the
white rectangle starts to increase in size.
Brightness and contrast controls are interactive. A change to one
may require a subtle change to the other in order to achieve the
optimum setting.
Note
Summary of Contents for CINEWIDETM VX-3000D
Page 2: ......
Page 10: ...x VX 3000d Series Installation Operation Manual P R E L I M I N A R Y Notes...
Page 76: ...Installation 60 VX 3000d Series Installation Operation Manual P R E L I M I N A R Y Notes...
Page 122: ...Specifications 106 VX 3000d Series Installation Operation Manual P R E L I M I N A R Y Notes...
Page 123: ......
Page 124: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1006 00 Rev B December 2009...