background image

Note:

 

Restricting the flow from a Rule pump by using a smaller 

pipe  or  hose  size  (such  as  a  garden  hose)  does  not  damage 
the pump, but will result in a reduction in flow. For maximum 
flow,  use  the  shortest  length  of  the  largest  diameter  hose 
available.

Installation Instructions 

Attach standard garden hose to the pump

.

Determine  the  location  for  the  pump  on  the  pool  cover. 
Generally  place  the  pump  where  the  water  would  be  the 
deepest. The installation must allow for complete drainage of 
the hose. All air/water pockets must be eliminated by having 
the garden hose, once it has started running downwardly, run 
level or continuously down There must be no loops or “sags” 
in the hose that could trap air or water.

2

1

Summary of Contents for H56SP-24

Page 1: ...FULLY AUTOMATIC POOL COVER DRAIN PUMP INSTRUCTION GUIDE Model H53SP 24 1800 GPH 110 VAC 60HZ 1 0 AMP Thermally Protected Enclosure 3 LISTED...

Page 2: ...the risk of electric shock replace damaged cord immediately Warning A clogged or frozen hose will prevent pump from discharging water To ensure proper flow please make sure hose is free of debris or...

Page 3: ...llation Instructions Attach standard garden hose to the pump Determine the location for the pump on the pool cover Generally place the pump where the water would be the deepest The installation must a...

Page 4: ...290 Replacement Pool Cover Drain Pump Strainer Base Model 278 Strainer Base for conversion to Utility Pump Model 68 Replacement Garden Hose Adapter Model 80 1 1 8 Corrugated Hose Connects to pump disc...

Page 5: ...ump in the event that it becomes embedded in ice or the impeller becomes jammed with debris Should the impeller jam due to ice no action is necessary The pump will resume its normal operation when the...

Page 6: ...source and remove strainer Remove debris from strainer and surrounding area Remove any debris from the impeller Disconnect pump from power source and remove blockage from pipes hoses and discharge po...

Page 7: ...approximately every 2 1 2 minutes During this check the pump runs for about one second and checks for resistance or drag against the impeller If resistance water is found it will run for as long as w...

Page 8: ...The Rule Guarantee We guarantee all our pumps to be free from factory defect or malfunction for two full years from purchase date 950 0049 REV K 11 2011...

Page 9: ...Rule Todas nuestras bombas cuentan con nuestra garant a de ausencia de defectos de f brica o desperfectos durante 2 a os completos a partir de la fecha de compra G A R A N T A D E A os A os 950 0049 R...

Page 10: ...encienden y comprueban el agua aproximada mente cada 2 1 2 minutos Durante esta comprobaci n la bomba funciona alrededor de 1 segundo y controla la resistencia contra el rotor En caso de detectar res...

Page 11: ...yacente Retire cualquier desperdicio que pueda tener el rotor Desconecte la bomba de la fuente de alimentaci n y retire cualquier obstrucci n que haya en las tuber as mangueras y en el puerto de desca...

Page 12: ...mba en caso de congelarse o de que el rotor se atasque con desperdicios Si el rotor se atasca debido a la presencia de hielo no es necesario que tome ninguna medida La bomba retomar su funcionamiento...

Page 13: ...de vaciado para cubiertas de piscinas Modelo 278 Base del filtro para conversi n a bomba auxiliar Modelo 68 Repuesto de adaptador de manguera de jard n Modelo 80 manguera corrugada de 1 1 8 Para cone...

Page 14: ...ci n Conecte una manguera com n de jard n a la bomba Determinar la ubicaci n de la bomba sobre la cubierta de la pisci na Por lo general este lugar ser a donde el agua es m s profunda La instalaci n d...

Page 15: ...na descarga el ctrica reemplace el cable da ado de inmediato Advertencia Una manguera obturada o congelada le impedir a la bomba descargar el agua Para asegurar una correcta circulaci n verifique que...

Page 16: ...BOMBA DE VACIADO PARA CUBIERTAS DE PISCINAS TOTALMENTE AUTOM TICA GU A DE INSTRUCCIONES Modelo H53SP 24 1800 GPH 110 VAC 60HZ 1 0 AMP Caja protegida t rmicamente 3 LISTED...

Reviews: